Feedline Connections
The
DXE-UN-43
UNUN is attached to the feedline antenna connection using the
DXE-TCB-
UNFK-WR
- UNUN Feed Point Connection Kit which contains one pre-drilled copper tinned braid
for connection to the vertical antenna system. The braid is 1" wide by 9" in length. Connect the
braid from the antenna feedpoint located on the base section of the antenna to the terminal on the
DXE-UN-43
UNUN closest to the
Red "+"
on the label as shown in
Figure 14
. Do not over
tighten the wing nuts. Hand tighten them only, do not use pliers or other tools to over tighten the
wing nuts.
Connect the other terminal on the
DXE-UN-43
UNUN closest to the
Black "
▬"
on the label to
the customer supplied radial system connection point.
Note:
Ensure the braid connection to the customer supplied radial connection does not interfere
with the tilting process.