13
Figure 8
uses a
DXE-FVC-1
Feedline Voltage Coupler to supply the switching voltages for a
system that has four different receive ports using three
DXE-RLS-2
Two Port Receive Antenna
Switches, one modified internally (refer to the
DXE-RLS-2
manual).
This four position switching system may be used for four antennas or four radio receivers.
Voltage Applied
only to Feedline
not to Ports
Selected Port
0 Vdc
Port A
+12 Vdc
Port B
-12 Vdc
Port C
12 Vac
Port D
Figure 8 - DXE-RLS-2 Configured to Switch 4 Ports