DX Engineering DXE-60VA-1P Скачать руководство пользователя страница 5

- 4  - 

WARNING! 

 

INSTALLATION OF ANY ANTENNA NEAR POWER LINES IS DANGEROUS 

 
 
 

 

Warning

:

 Do not locate the antenna near overhead power lines or other electric light or power 

circuits, or where it can come into contact with such circuits.  When installing the antenna, take 
extreme care not to come into contact with such circuits, because they may cause serious injury or 
death.  
 

Overhead Power Line Safety 

Before you begin working, check carefully for overhead power lines in the area you will be 
working.  Don't assume that wires are telephone or cable lines: check with your electric utility for 
advice. Although overhead power lines may appear to be insulated, often these coverings are 
intended only to protect metal wires from weather conditions and may not protect you from electric 
shock 

 

Keep your distance! Remember the 10-foot rule:  When carrying and using ladders and other long 
tools, keep them at least 10 feet away from all overhead lines - including any lines from the power 
pole to your home. 
 
 

Installation 

 

Site Selection 

Select a mounting location clear from power lines, structures and other antennas by a minimum of 
53 feet (43 plus 10 for the 10 foot safety rule). 

Consider overhead power lines, utility cables and 

wires

. The further away the vertical is mounted from local noise sources or other metallic objects, 

which can re-radiate noise and affect the tuning, radiation pattern and 
SWR, the better. When using the Tilt Base, determine the direction you 
want the antenna to tilt down and make sure there is adequate clearance. 
There should be sufficient room for a radial system that will extend away 
from the antenna equally in all directions, if possible. 
 

 

Mounting Pipe 

Use a customer supplied thick-walled galvanized steel mounting pipe 

at 

least

 4 feet long. This will allow approximately 2 feet or more to be below 

ground and approximately 2 feet above ground. A thick-walled steel pipe 
1-3/4" OD to 2" OD 

maximum

 is recommended with a minimum 

thickness of 1/8" (1/4" preferred) should be used. The standard 1-1/2" 
galvanized water pipe (with its 1.9" OD) is just fine for this application 
and can usually be found at your local home building supply store. For 
permanent mounting, use a post-hole digger to make the hole deep enough 
to accommodate 2 feet of pipe and a couple inches of gravel at the bottom 

Содержание DXE-60VA-1P

Страница 1: ...Vertical Antenna DXE 60VA 1P DXE 60VA 1P INS Revision 13d DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E ma...

Страница 2: ...nting Pipe 7 Attaching Ground Radial Wires to the Radial Plate 7 Tilt Base to Mounting Pipe 8 Vertical Base Section 8 Base Section to Tilt Base 10 Assembling the Vertical Element Sections 12 Mating th...

Страница 3: ...thickness 4 feet long The standard 1 1 2 galvanized water pipe with its 1 9 OD is just fine for this application and can usually be found at your local home building supply store Quik Set Concrete Mo...

Страница 4: ...4 1 500 x 0 058 x 72 Tube Slit both ends 1 1 4 Fender Washer 1 OD 4 Element Clamps 8 1 4 20 Flanged Nut 2 Black Vinyl Cap 1 1 4 20 Nyloc nut 4 3 8 U Bolt x 2 ID x 3 25 leg 2 Feedpoint Connection 2 Sa...

Страница 5: ...r from power lines structures and other antennas by a minimum of 53 feet 43 plus 10 for the 10 foot safety rule Consider overhead power lines utility cables and wires The further away the vertical is...

Страница 6: ...th black relaxed PVC insulation wire is suggested for the best results The wire radials should placed as symmetrically as possible around the vertical antenna and spaced evenly regardless of how many...

Страница 7: ...the optional DXE RADP 3 Radial Plate The standard 1 1 2 galvanized water pipe with its 1 9 OD is just fine for this application and can usually be found at your local home building supply store Radia...

Страница 8: ...ure 2 Radial Wire Hardware Installation Tilt Base to Mounting Pipe Install the Tilt Base to the 2 OD maximum mounting pipe using two DXE SSVC 2P V Clamps allowing approximately 7 clearance between the...

Страница 9: ...From the inside of the channel insert a 2 bolt with a flat washer through each of the middle four holes through the backing plate Put on the aluminum spacer a split washer and a hex nut Tighten firml...

Страница 10: ...and four nuts as shown in Figure 6 The base section element tube should extend approximately 1 1 4 beyond the bottom of the U bolt clamp When tightening observe the split washers When they fully seat...

Страница 11: ...10 Base Section to Tilt Base Place the Lower Base Section into the holes of the Tilt Base and loosely install the Tilt Base mounting hardware shown in Figure 7 Figure 7...

Страница 12: ...he antenna It is important to note that the lower outside bolt becomes the pivot point while raising or lowering the antenna This pivot bolt MUST be retained in the pivot point It seems natural to pus...

Страница 13: ...d further assure that there are no ragged edges or protrusions Use the DXE 22166 Slim Grip Deburring Tool or the DXE 22600 Deburring Tool with Extending Handle and Extra Blades for this operation 2 Cl...

Страница 14: ...element clamp should be positioned between the slits in the elements and 1 8 from the edge of each element as shown in Figure 9 Figure 9 Using Figure 10 and Figure 11 for dimensions assemble the 1 1 2...

Страница 15: ...14 Figure 10...

Страница 16: ...15 Figure 11 60VA 1P Section Dimensions...

Страница 17: ...lack vinyl cap in place at the top of the smallest element section Raising the Vertical DANGER Make sure you have not inadvertently located the antenna underneath power lines Residential power lines a...

Страница 18: ...ient way to make a reliable feedline connection using customer supplied coaxial cable is using the optional DXE RADP 3 Radial Plate with the optional DXE 112 KIT SO 239 Chassis Mount Connector as show...

Страница 19: ...added benefit the DXE VMN 1 it will act as a static bleed for your vertical antenna in areas where precipitation static or snow static is present 1 Use a small Phillips head screwdriver to loosen the...

Страница 20: ...own and proceed as follows Adjust the tap clip by moving the tap clip to a different coil turn on the DXE VMN 1 Coil for minimum SWR on 60 meters Disregard any frequency shift of the points of lowest...

Страница 21: ...tably different from a full length quarter wave vertical on that band If you have not already added it the DXE VMN 1 Vertical Antenna Matching Network will allow precise adjustment of VSWR after setti...

Страница 22: ...al antenna installations with excellent radial systems achieving the best SWR on a resonant monoband vertical may be difficult without some means of adjusting feedpoint impedance The DXE VMN 1 allows...

Страница 23: ...maximum grip Soldering is not required for strength but is recommended if installed in corrosive environments such as salt spray Packed 20 Radial Wires per package 14 gage stranded copper wire Black...

Страница 24: ...ts manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a period of one 1 year from date of shipment DX Engineering s sole obligation under these warran...

Отзывы: