DX Engineering DXE-60VA-1P Скачать руководство пользователя страница 24

- 23  - 

DXE-GUY-Kits  -  Guying Kit for Vertical Antennas  

Some vertical manufacturers indicate their antennas do not need guying. During times of high winds or ice loading, some 
of these verticals may sustain damage or fail altogether. With the small amount of effort needed to install a four point 
guying system, the risk hardly seems worth taking. A four-point guying scheme provides the best mechanical advantage to 
reduce wind stress, regardless of direction. A four point guying system is recommended for use with a DX Engineering 
Tilt Base, because just one of the guy ropes has to be loosened when you tilt the vertical down. The remaining guys help 
stabilize the vertical in three directions when being raised. These Vertical Guying kits have been designed to be used with 
ground mounted vertical antenna systems. The guying kits are ideal for fixed or portable installations.  
 

DXE-GUY100-KIT 

4 - Heavy Duty screw-in earth anchors with eyelets 
1 - 100 ft Roll - UV resistant, 3/32 Double-Braided Dacron Polyester Rope SYN-DBR-94-100 

DXE-GUY200-KIT 

4 - Heavy Duty screw-in earth anchors with eyelets 
2 - 100 ft Rolls - UV resistant, 3/32 Double-Braided Dacron Polyester Rope SYN-DBR-94-100 

DXE-GUY400-KIT 

4 - Heavy Duty screw-in earth anchors with eyelets 
4 - 100 ft Rolls - UV resistant, 3/32 Double-Braided Dacron Polyester Rope SYN-DBR-94-100 

DXE-GUY1000-KIT 

4 - Heavy Duty screw-in earth anchors with eyelets 
1 - 1000 ft Roll - UV resistant, 3/32 Double-Braided Dacron Polyester Rope SYN-DBR-94-1000 

 
DXE-22600  -  Deburring Tool with Extending Handle and 2 Blades

 

Handy for cleaning burrs after cutting or drilling aluminum or steel.  This rugged hand tool features an adjustable length blade holder 
to allow access to burrs deep inside tubing or other hard to reach places.  Extremely versatile and handy. 

 

Includes one blade for aluminum and steel and one blade for cast iron and brass.  

 

Holder telescopes from 1⁄2" to 5" for long reach inside objects.  

 

Handle has storage compartment for spare blades.  

 

Blade can be inserted at 90° for deburring cross holes.  

 
Technical Support 

 

If you have questions about this product, or if you experience difficulties during the installation, 
contact DX Engineering at (330) 572-3200.  You can also e-mail us at:       

 
 

[email protected]

 

 

For best service, please take a few minutes to review this manual before you call. 

 

Warranty

 

 

All products manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a period of one (1) year from 
date of shipment. DX Engineering’s sole obligation under these warranties shall be to issue credit, repair or replace any item or part thereof which is 
proved to be other than as warranted; no allowance shall be made for any labor charges of Buyer for replacement of parts, adjustment or repairs, or 
any other work, unless such charges are authorized in advance by DX Engineering.  If DX Engineering’s products are claimed to be defective in 
material or workmanship, DX Engineering shall, upon prompt notice thereof, issue shipping instructions for return to DX Engineering (transportation-
charges prepaid by Buyer). Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing. The above 
warranties shall not extend to any products or parts thereof which have been subjected to any misuse or neglect, damaged by accident, rendered 
defective by reason of improper installation, damaged from severe weather including floods, or abnormal environmental conditions such as prolonged 
exposure to corrosives or power surges, or by the performance of repairs or alterations outside of our plant, and shall not apply to any goods or parts 
thereof furnished by Buyer or acquired from others at Buyer’s specifications. In addition, DX Engineering’s warranties do not extend to other 
equipment and parts manufactured by others except to the extent of the original manufacturer’s warranty to DX Engineering.  The obligations under 
the foregoing warranties are limited to the precise terms thereof. These warranties provide exclusive remedies, expressly in lieu of all other remedies 
including claims for special or consequential damages. SELLER NEITHER MAKES NOR ASSUMES ANY OTHER WARRANTY 
WHATSOEVER, WHETHER EXPRESS, STATUTORY, OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND 
FITNESS, AND NO PERSON IS AUTHORIZED TO ASSUME FOR DX ENGINEERING ANY OBLIGATION OR LIABILITY NOT STRICTLY 
IN ACCORDANCE WITH THE FOREGOING. 
 
©DX Engineering 2013 
 
DX Engineering

®

, DXE

®

, DX Engineering, Inc.

®

, Hot Rodz®, Maxi-Core

®

, DX Engineering THUNDERBOLT

®

, DX Engineering Yagi Mechanical

®

EZ-BUILD

®

, TELREX

®

 and Gorilla Grip

®

 Stainless Steel Boom Clamps, are trademarks of PDS Electronics, Inc. No license to use or reproduce any 

of these trademarks or other trademarks is given or implied. All other brands and product names are the trademarks of their respective owners.  
  
Specifications subject to change without notice. 
 
 

Содержание DXE-60VA-1P

Страница 1: ...Vertical Antenna DXE 60VA 1P DXE 60VA 1P INS Revision 13d DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E ma...

Страница 2: ...nting Pipe 7 Attaching Ground Radial Wires to the Radial Plate 7 Tilt Base to Mounting Pipe 8 Vertical Base Section 8 Base Section to Tilt Base 10 Assembling the Vertical Element Sections 12 Mating th...

Страница 3: ...thickness 4 feet long The standard 1 1 2 galvanized water pipe with its 1 9 OD is just fine for this application and can usually be found at your local home building supply store Quik Set Concrete Mo...

Страница 4: ...4 1 500 x 0 058 x 72 Tube Slit both ends 1 1 4 Fender Washer 1 OD 4 Element Clamps 8 1 4 20 Flanged Nut 2 Black Vinyl Cap 1 1 4 20 Nyloc nut 4 3 8 U Bolt x 2 ID x 3 25 leg 2 Feedpoint Connection 2 Sa...

Страница 5: ...r from power lines structures and other antennas by a minimum of 53 feet 43 plus 10 for the 10 foot safety rule Consider overhead power lines utility cables and wires The further away the vertical is...

Страница 6: ...th black relaxed PVC insulation wire is suggested for the best results The wire radials should placed as symmetrically as possible around the vertical antenna and spaced evenly regardless of how many...

Страница 7: ...the optional DXE RADP 3 Radial Plate The standard 1 1 2 galvanized water pipe with its 1 9 OD is just fine for this application and can usually be found at your local home building supply store Radia...

Страница 8: ...ure 2 Radial Wire Hardware Installation Tilt Base to Mounting Pipe Install the Tilt Base to the 2 OD maximum mounting pipe using two DXE SSVC 2P V Clamps allowing approximately 7 clearance between the...

Страница 9: ...From the inside of the channel insert a 2 bolt with a flat washer through each of the middle four holes through the backing plate Put on the aluminum spacer a split washer and a hex nut Tighten firml...

Страница 10: ...and four nuts as shown in Figure 6 The base section element tube should extend approximately 1 1 4 beyond the bottom of the U bolt clamp When tightening observe the split washers When they fully seat...

Страница 11: ...10 Base Section to Tilt Base Place the Lower Base Section into the holes of the Tilt Base and loosely install the Tilt Base mounting hardware shown in Figure 7 Figure 7...

Страница 12: ...he antenna It is important to note that the lower outside bolt becomes the pivot point while raising or lowering the antenna This pivot bolt MUST be retained in the pivot point It seems natural to pus...

Страница 13: ...d further assure that there are no ragged edges or protrusions Use the DXE 22166 Slim Grip Deburring Tool or the DXE 22600 Deburring Tool with Extending Handle and Extra Blades for this operation 2 Cl...

Страница 14: ...element clamp should be positioned between the slits in the elements and 1 8 from the edge of each element as shown in Figure 9 Figure 9 Using Figure 10 and Figure 11 for dimensions assemble the 1 1 2...

Страница 15: ...14 Figure 10...

Страница 16: ...15 Figure 11 60VA 1P Section Dimensions...

Страница 17: ...lack vinyl cap in place at the top of the smallest element section Raising the Vertical DANGER Make sure you have not inadvertently located the antenna underneath power lines Residential power lines a...

Страница 18: ...ient way to make a reliable feedline connection using customer supplied coaxial cable is using the optional DXE RADP 3 Radial Plate with the optional DXE 112 KIT SO 239 Chassis Mount Connector as show...

Страница 19: ...added benefit the DXE VMN 1 it will act as a static bleed for your vertical antenna in areas where precipitation static or snow static is present 1 Use a small Phillips head screwdriver to loosen the...

Страница 20: ...own and proceed as follows Adjust the tap clip by moving the tap clip to a different coil turn on the DXE VMN 1 Coil for minimum SWR on 60 meters Disregard any frequency shift of the points of lowest...

Страница 21: ...tably different from a full length quarter wave vertical on that band If you have not already added it the DXE VMN 1 Vertical Antenna Matching Network will allow precise adjustment of VSWR after setti...

Страница 22: ...al antenna installations with excellent radial systems achieving the best SWR on a resonant monoband vertical may be difficult without some means of adjusting feedpoint impedance The DXE VMN 1 allows...

Страница 23: ...maximum grip Soldering is not required for strength but is recommended if installed in corrosive environments such as salt spray Packed 20 Radial Wires per package 14 gage stranded copper wire Black...

Страница 24: ...ts manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a period of one 1 year from date of shipment DX Engineering s sole obligation under these warran...

Отзывы: