background image

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

©Copyright 2013 Dwyer Instruments, Inc

Printed in U.S.A. 1/14

FR# 19-443779-00 Rev.4

3

-5

/6

4

[7

8

.2

7

]

S

T

A

N

D

A

R

D

 M

O

U

N

T

IN

G

 H

O

L

E

D

IM

E

N

S

IO

N

 F

O

R

 D

IG

IM

A

G

 G

A

U

G

E

Ø

4

-9

/1

6

 [

1

1

5

.8

9

]

1

[2

5

.4

4

]

2

X

3

0

°

2

x

Ø

1

3

/3

2

 [

1

0

.3

2

]

T

H

R

U

 H

O

L

E

S

 F

O

R

 

P

R

E

S

S

U

R

E

 P

O

R

T

S

1

-5

1

/6

4

 [

4

5

.7

2

]

3

-1

5

/3

2

 [

8

8

.1

2

]

(3

S

U

R

F

A

C

E

 M

O

U

N

T

IN

G

H

O

L

E

 L

O

C

A

T

IO

N

S

1

3

/3

2

 [

1

0

.1

6

]

Ø

5

/8

 [

1

5

.8

8

]

T

H

R

U

 H

O

L

E

 F

O

R

C

O

N

D

U

IT

 C

O

N

N

E

C

T

IO

N

O

U

T

S

ID

E

 D

IA

M

E

T

E

R

O

F

 A

-2

8

6

 F

L

A

N

G

E

1

-1

/4

 [

3

1

.7

5

]

(3

F

L

A

N

G

E

 M

O

U

N

T

IN

G

H

O

L

E

 L

O

C

A

T

IO

N

S

Ø

5

-1

7

/3

2

 [

1

4

0

.4

9

]

B

O

L

T

 C

IR

C

L

E

M

O

U

N

T

IN

G

 H

O

L

E

 D

IM

E

N

S

IO

N

F

O

R

 A

-2

8

6

 F

L

A

N

G

E

Ø

5

-1

/8

 [

1

3

0

.1

8

]

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание Series DM-1000

Страница 1: ...ECIFICATIONS Service Air and non combustible compatible gases Wetted Materials Consult factory Housing Materials Glass filled plastic Accuracy 1 F S including linearity hysteresis and repeatability 2 F S for ranges 1 w c and below Temperature Limits 0 to 140 F 18 to 60 C Compensated Temperature Limits 32 to 122 F 0 to 50 C Long Term Stability 1 F S per year Thermal Effect 0 05 F S F typ 0 10 F S F...

Страница 2: ...tallation The unit is shipped with a separate 9V alkaline battery Remove the unit s top back cover do not remove bottom cover Connect the 9V battery to the battery holder as shown in Figure 1 Replace top back cover and tighten screws to 2 25 in lbs External Power Supply Installation Remove the unit s back cover then connect the external power supply to the terminal block as shown in Figure 1 OPERA...

Страница 3: ...Menu Map www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 4: ...ation SUB MENUS for Series DM 1100 is PrES INWC Pressure Unit PRESSURE SUB MENU PRES INWC PrES INWC Pressure inches of water column With the LCD reading PrES INWC press the E key the display will blink Press the q key to change the pressure unit then press the E key to save the desired unit For pressure measurement the following units are available INWC Inches of water column MBAR Millibar PSI Pou...

Страница 5: ...1 Depending on the Display Update setting the battery life is shown below 150 hours typical if Display Update is set for Normal 1 second update rAtE NORM 9 months typical if Display Update is set for 10 minutes rAtE 10 1 5 years typical if Display Update is disabled rAtE KEY 2 If the Display Update is set for 10 minutes or disabled On Touch mode the process pressure value can be read instantly by ...

Страница 6: ...LE DIMENSION FOR DIGIMAG GAUGE Ø4 9 16 115 89 1 25 44 2X30 2xØ13 32 10 32 THRU HOLES FOR PRESSURE PORTS 1 51 64 45 72 3 15 32 88 12 3 SURFACE MOUNTING HOLE LOCATIONS 13 32 10 16 Ø5 8 15 88 THRU HOLE FOR CONDUIT CONNECTION OUTSIDE DIAMETER OF A 286 FLANGE 1 1 4 31 75 3 FLANGE MOUNTING HOLE LOCATIONS Ø5 17 32 140 49 BOLT CIRCLE MOUNTING HOLE DIMENSION FOR A 286 FLANGE Ø5 1 8 130 18 www GlobalTestSup...

Отзывы: