background image

Bulletin P-DM-1100

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

Specifications - Installation and Operating Instructions

Series DM-1000 DigiMag

®

Digital Differential Pressure Gage

The  Series  DM-1000  DigiMag

®

Digital  Differential  Pressure  Gage

is  the  ideal

digital  instrument  to  take  the  place  of  analog  mechanical  pressure  gages.  The
DigiMag

®

Digital Gages are more versatile than analog gages with their ability to be

field-programmed  to  display  many  commonly  used  engineering  units  as  well  as
percent  of  full  scale.  The 

Series  DM-1000

can  be  programmed  in  8  commonly

used engineering units plus percent of full scale. This capability allows quick units
selection on site, eliminating the need to calculate various unit conversions. The
DigiMag

®

Digital  Differential  Pressure  Gages  have  an  added  feature  for  filter

applications where a set point can be input where the display will blink when the
filter is dirty, alerting the user that a maintenance action needs to occur.  

Programming  the  Series  DM-1000  is  easy  using  the  menu  key  to  access  4
simplified menus which provide access to: Security level; engineering units; filter
set  point;  view  peak  and  valley  process  readings;  digital  damping  for  smoothing
erratic process applications; display update to conserve battery life; zero and span
field calibration.

The Series DM-1000 DigiMag

®

Digital Differential Pressure Gage possesses a full

scale accuracy of 1% on ranges down to 2˝ w.c. and 2% accuracy down to the very
low ranges of 1” to 0.25" w.c. Models are also available with bi-directional ranges.
DigiMag

®

Digital Differential Pressure Gages offer power versatility by working with

9-24  VDC  line  power  or  simply  9V  battery  power.  If  using  line  power  and
connecting the 9V battery, the battery will act as a back-up if line power is lost or
interrupted.  

SPECIFICATIONS
Service: 

Air and non-combustible, compatible gases.

Wetted Materials:

Consult factory.

Housing Materials:

Glass filled plastic.

Accuracy:

±1% F.S. including linearity, hysteresis and repeatability; ±2% F.S. for

ranges 1˝ w.c. and below.

Temperature Limits:

0 to 140°F (-18 to 60°C).

Compensated Temperature Limits:

32 to 122°F (0 to 50°C).

Long Term Stability:

±1% F.S. per year.

Thermal Effect:

±0.05% F.S./°F typ.; ±0.10% F.S./°F for ranges 1˝ w.c. and

below.

Display:

4-digit LCD (Digits: 0.60˝H x 0.33˝W).

Display Update:

Selectable for 1 second to 10 minutes or update only from

button push.

Pressure Limits: 

Normal and bi-directional ranges 5˝ w.c. and lower = 2 psi

(13.7 kPa); Normal and bi-directional ranges 10˝ w.c. and higher = 11 psi (75
kPa).

Selectable Engineering Units:

in w.c., psi, kPa, Pa, mm w.c., mBar, in Hg, mm

Hg, FS (0-100%).

Power Requirements:

9V battery or external power supply 9-24 VDC. Battery

included but not connected.

Type of Battery:

9V alkaline battery (Duracell

®

PC 1604 or equivalent).

Battery Service Life:

Battery life depending on the Display Update setting: 150

hours (typical) if Display Update = 1 second; 9 month (typical) if Display Update =
10 minutes; 1.5 years (typical) if Display Update is disabled. Battery may last up
to four times longer when using lithium-based battery ULTRALIFE U9VL-J.

Current Consumption:

5 mA maximum.

Electrical Connections:

Removable terminal block for 16 to 26 AWG.

Electrical Entry:

Cable gland for 0.114 to 0.250˝ (2.9 to 6.4 mm) diameter cable.

Process Connections: 

3/16˝ I.D. tubing (5 mm I.D.), maximum O.D. 3/8˝ tubing.

Enclosure Rating:

NEMA 4X (IP66).

Weight:

1.18 lb (535 g).

Size:

5˝ (127 mm) O.D. front face.

Agency Approvals:

CE, EN 61326-1 [Immunity Test Requirement for Industrial

Environments] with the following SPEC:
IEC 61000-3-2
IEC 61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11

Duracell

®

is a registered trademark of The Gillette Company.

4-31/64

[113.89]

3X1/8

[3.30]

1-59/64

[48.89]

17/64

[6.91]

Ø5

[127.00]

PRESSURE

CONNECTIONS

21/64 [8.59] LONG

3-5/64

[78.27]

1

[25.44]

3-15/32

[88.12]

Ø13/64

[5.18]

Ø25/64
[10.03]

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание Series DM-1000

Страница 1: ...ECIFICATIONS Service Air and non combustible compatible gases Wetted Materials Consult factory Housing Materials Glass filled plastic Accuracy 1 F S including linearity hysteresis and repeatability 2 F S for ranges 1 w c and below Temperature Limits 0 to 140 F 18 to 60 C Compensated Temperature Limits 32 to 122 F 0 to 50 C Long Term Stability 1 F S per year Thermal Effect 0 05 F S F typ 0 10 F S F...

Страница 2: ...tallation The unit is shipped with a separate 9V alkaline battery Remove the unit s top back cover do not remove bottom cover Connect the 9V battery to the battery holder as shown in Figure 1 Replace top back cover and tighten screws to 2 25 in lbs External Power Supply Installation Remove the unit s back cover then connect the external power supply to the terminal block as shown in Figure 1 OPERA...

Страница 3: ...Menu Map www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 4: ...ation SUB MENUS for Series DM 1100 is PrES INWC Pressure Unit PRESSURE SUB MENU PRES INWC PrES INWC Pressure inches of water column With the LCD reading PrES INWC press the E key the display will blink Press the q key to change the pressure unit then press the E key to save the desired unit For pressure measurement the following units are available INWC Inches of water column MBAR Millibar PSI Pou...

Страница 5: ...1 Depending on the Display Update setting the battery life is shown below 150 hours typical if Display Update is set for Normal 1 second update rAtE NORM 9 months typical if Display Update is set for 10 minutes rAtE 10 1 5 years typical if Display Update is disabled rAtE KEY 2 If the Display Update is set for 10 minutes or disabled On Touch mode the process pressure value can be read instantly by ...

Страница 6: ...LE DIMENSION FOR DIGIMAG GAUGE Ø4 9 16 115 89 1 25 44 2X30 2xØ13 32 10 32 THRU HOLES FOR PRESSURE PORTS 1 51 64 45 72 3 15 32 88 12 3 SURFACE MOUNTING HOLE LOCATIONS 13 32 10 16 Ø5 8 15 88 THRU HOLE FOR CONDUIT CONNECTION OUTSIDE DIAMETER OF A 286 FLANGE 1 1 4 31 75 3 FLANGE MOUNTING HOLE LOCATIONS Ø5 17 32 140 49 BOLT CIRCLE MOUNTING HOLE DIMENSION FOR A 286 FLANGE Ø5 1 8 130 18 www GlobalTestSup...

Отзывы: