DVS Filters

For your safety

Please take special care when climbing into your roof space, and while in the roof space walk only on 

load-bearing roof beams or trusses.  We suggest you ensure another person is in the house or tell a 

neighbour you are climbing into your roof space so that you can get assistance quickly if you slip or 

have an accident.

Switch your DVS SYSTEM OFF at the control panel.

Disconnect the DVS Air Handling Unit from the house supply by unplugging the 3-pin plug before 

servicing or changing the air filters. Use only a dry cloth when cleaning the unit. Do NOT remove, open 

or attempt to service any DVS equipment while it is connected to the house power supply.

DVS filters meet international air quality ratings and remove dust, pollen, plant spores and other 

airborne material from your air supply prior to delivering this into your home.

We recommend that you replace the air filters on your DVS system every 12 months.  A blocked air 

filter can cause poor performance from your DVS and may result in equipment damage or failure that 

could shorten the life of your DVS system.  We supply replacement filters, which can be fitted by 

yourself, or can be fitted by our service technicians in conjunction with a service check of your DVS 

system.

Please contact DVS on 0800 387 387 to organise a service technician to do this for you. Alternatively, 

follow the instructions provided to change the filters yourself.

IMPORTANT INFORMATION

You need to replace your filters every 12 months with genuine DVS® branded filters to maintain correct 
operation of the system. The 5 Year Parts and Labour Warranty on your DVS® system is dependant on you 
doing so during its period of validity. 

Содержание DVSG4

Страница 1: ...DVS Reclaim Home Ventilation System Operating Guide Enjoy a healthier more comfortable home DVS Reclaim 19o...

Страница 2: ...m off or on 5 Fan boost option 5 Advanced functions 5 Adjusting the fan speed 6 Automatic summer bypass 6 Automatic roofspace bypass 7 Utilities 8 Setting the clock 8 View temperature history graphs 8...

Страница 3: ...as an automatic summer bypass or a roof space bypass are available as add on extras These operating guidelines contain helpful instructions on how to operate and adjust your system Although your syste...

Страница 4: ...ey are in use the Main Screen will also show The status of the Summer bypass function if fitted The status of the roof bypass function if fitted Whether the filter is due for replacement Note If the L...

Страница 5: ...fore exhausting it outside 3 The second fan draws a constant supply of filtered fresh outdoor air into your home 4 The energy recovered by the heat exchanger is transferred to this incoming fresh air...

Страница 6: ...ful for clearing the house of extra moisture or smells Please note that the fan may be noisier at this speed To set the length of time for Fan Boost or to turn it off Press and hold the up arrow for 3...

Страница 7: ...The purpose of an Automatic Summer Bypass is to deliver a continuous supply of fresh filtered air from outside by automatically changing the air source to draw directly from the external vent and byp...

Страница 8: ...oof space air is just providing additional heat in the form of solar gain to the exhaust air This function will automatically activate once the roofspace temperature exceeds the bypass set temperature...

Страница 9: ...urs Press OK again to display Temp graph 2 which shows the previous 7 days Press the Menu button Filter Service The filter reminder will appear on the Main Screen when the filter service timer has cou...

Страница 10: ...ove dust pollen plant spores and other airborne material from your air supply prior to delivering this into your home We recommend that you replace the air filters on your DVS system every 12 months A...

Страница 11: ...ters duct tape a clean dry cloth and a good torch or safety lamp Remove the existing black duct tape from the ducting at the end closest to the outside air vent opposite end to the fan Remove the duct...

Страница 12: ...p home Don t be afraid to adjust and customise your settings to achieve a good balance between condensation control and airflow especially in colder seasons Your DVS ventilation system has been indivi...

Страница 13: ...tlets in the affected rooms is an easy way to ensure privacy and solve condensation problems in rooms where people prefer to close doors at night To discuss this option please call us on 0800 387 387...

Страница 14: ...uring winter months than before the DVS was installed This is because in order to control condensation mould mildew and dampness problems during colder seasons the DVS system must continue to bring ai...

Страница 15: ...ernally vented extract fans are now mandatory for all new homes under the Building Code Draught Proofing Draught proofing is one of the cheapest and most efficient ways to save energy in your home and...

Страница 16: ...there dust on the ceiling outlet or on the ceiling near the outlet This sometimes happens usually as a result of dust already in the home being attracted by static electricity due to the drier air fr...

Страница 17: ...st or bypass mode If the DVS system is making clunking or clicking noises or is very noisy it may indicate that an Air Handling Unit is damaged or worn Please contact us on 0800 DVS DVS 0800 387 387 W...

Страница 18: ...today s safe easy and economical way to keep individual rooms or your whole home comfortable all year round You ll be warm and cosy in winter and cool and refreshed in summer The award winning Fujitsu...

Страница 19: ...17a Piermark Drive Rosedale North Shore City Auckland 0632 T 0800 387 387 www dvs co nz...

Отзывы: