The operation of the water heater must be 
tested by the installer. This work must only 
be done by a licensed tradesperson.

Test for Leaks:

Check the water inlet, water outlet and gas 
inlet pipe work and connections for leaks.

Test the Gas Inlet Pressure:

For correct operation of the water heater, 
the gas inlet pressure must be at least:
  

Natural Gas 

1.13 kPa 

 

Propane  

2.75 kPa

To test the gas inlet pressure, follow the 
procedure below. If the pressure is less 
than the above value, there could be a 
problem with the gas meter or supply 
pipe size. 
1.  Ensure the water heater has been 

filled with water and the gas isolation 
valve is turned off.

2.  Remove the lower of the two hex 

head screws on the right hand side 
of the gas control valve and fit a 
manometer to the spigot.

3.  Turn on the gas isolation valve and 

light the water heater. See Lighting 
the Water Heater on page 8.

4.  If necessary, adjust the control knob 

until the main burner lights.

5.  With the main burner alight, measure 

the pressure.

6.  Turn the thermostat knob to the “•” 

(off) position and turn off the gas 
isolation valve.

7.  Disconnect the manometer and 

replace the screw removed at  
step 2.

Test the Gas Test Point Pressure:

For correct operation of the water heater, 
the gas test point pressure must be 
within 5% of the value marked on the 
compliance plate.

4 Star:  

To test the gas test point 
pressure, follow the same 
procedure used for the gas inlet 
pressure except that the upper of 
the two hex head screws is to be 
removed at step 2. 

5 Star:  

To test the gas test point 
pressure, follow the same 
procedure used for the gas inlet 
pressure except that the M4 
button head screw on the right 
hand side of the relay valve is to 
be removed at step 2. A 2.5mm 
allen key is supplied with the 
water heater for this purpose.

If the pressure is not within 5% of the 
marked value, contact Dux After Sales 
and Service for advice.

Final Checks:

•  Turn on the gas isolation valve and 

light the water heater.

•  Make sure there are no gas leaks 

from either of the two screws 
removed during gas pressure testing.

•  Set the gas control knob to position 

“6” unless hot water is not required.

•  Replace the access cover.
•  Hand this manual to the occupier of 

the premises and explain the lighting 
procedure if required.

Testing

Содержание 135DC5N

Страница 1: ...and transit protection from the heater before installation Dispose of the packaging responsibly using re cycling facilities where they exist H3109 3109 Rev L 4 Star Models 135ZB4N 135ZB4P 170ZB4N 170Z...

Страница 2: ...ts 1 Specifications 4 Plumbing Connections 5 Gas Connection and Filling 7 Lighting the Water Heater 8 Shut Down and Draining 9 Testing 10 Owner s Information 11 System Maintenance 13 Considering a Ser...

Страница 3: ...vailable Dux recommends that installations conform to AS NZS 3500 4 Note for Victoria This water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a lic...

Страница 4: ...ommon clearance requirements are set out below At least 300 mm below any eaves balconies or other projections Note that at least half the height of the water heater is recommended as clearance to prov...

Страница 5: ...fixed to the wall with suitable fasteners and fixed to the water heater with the self drilling screws provided Water Supply This water heater has been manufactured to suit the water conditions of mos...

Страница 6: ...ressure Min 1 13 kPa 2 75 kPa 1 13 kPa 2 75 kPa Gas Supply Pressure Max 3 50 kPa 3 50 kPa 3 50 kPa 3 50 kPa Nominal Dimensions 135L 170L A Overall Height mm 1600 1895 B Outlet Height mm 1325 1620 C In...

Страница 7: ...to enable connection of the water heater to supplementary energy sources such as solar panels or slow combustion stoves Refer to AS NZS 3500 4 for guidance on these types of installations Fit the insu...

Страница 8: ...y the relevant Authority Plastic pipes or fittings shall not be used between the isolating valve and the inlet See the diagram below for details Water Supply Pressure This water heater is designed for...

Страница 9: ...e before the connections are completed The grommet must then be clipped into the case A union should be used to connect the gas pipe to the RP DN15 socket on the gas control valve Ensure that the unio...

Страница 10: ...b depressed repeatedly press the igniter button for up to 40 seconds until the pilot flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its...

Страница 11: ...heater by carrying out the steps listed at left 2 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to release the pressure in the water heater 3 Disconnect the cold water...

Страница 12: ...the thermostat knob to the off position and turn off the gas isolation valve 7 Disconnect the manometer and replace the screw removed at step 2 Test the Gas Test Point Pressure For correct operation...

Страница 13: ...Relief PTR Valve must be installed directly into the top socket marked RELIEF VALVE The PTR Valve rating is shown on the compliance plate The valve must not be tampered with or removed The water heat...

Страница 14: ...ot expecting to need hot water for more than a few days the control knob on the gas control valve thermostat can be set to the pilot position to conserve energy Alternatively the water heater can be s...

Страница 15: ...r than this personally inspecting or servicing any part of the water heater is not recommended Annual Service This service should only be carried out by a licensed tradesperson We recommend your local...

Страница 16: ...water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve discha...

Страница 17: ...er parts 1 year The benefits provided to you by this warranty are in addition to any other rights and remedies available to you under the Australian Consumer Law Parts and Labour Warranty Dux Manufact...

Страница 18: ...ation of Dux to make the water heater accessible for repair or replacement Where the Dux water heater is located outside the metropolitan area of a capital city and is more than 100km from a Dux offic...

Страница 19: ...ailure If Dux fails to meet a guarantee under the ACL your remedy for such failure may be limited to any one or more of the following replacement of the water heater repair of the water heater refundi...

Страница 20: ...warranty Please Register Your Water Heater Please take a moment to fill out your details for warranty registration at This will ensure all your current details are registered with us for prompt warra...

Отзывы: