![DutchWest 2478 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/dutchwest/2478/2478_homeowners-installation-and-operating-manual_2543490014.webp)
14
Dutchwest
®
Non-Catalytic Convection Heater
30002278
Distance from Center of Flue Collar to Wall in Top-Exit Installations
Dutchwest Convection Heater Model 2478
NOTE: These are not clearance distances. These measurements indicate where the centerline of the lue col-
lar will be for various installations. Measurements are from the centerline of the lue collar to the wall, not the
wall protector.
A
B
C
E
D
F
C
F
Chimney Connector
Side
Rear
Corner
Side
Rear
Corner
Listed, Approved
(A) 30”
(B) 13”
(C) 18
¹⁄₂
”
(D) 21”
(E) 12
¹⁄₂
”
(F) 18”
Double-wall, with
(762 mm)
(330 mm) (470 mm)
(533 mm)
(318 mm)
(457 mm)
lue collar shield
Single wall, with
(A) 27”
(B) 13”
(C) 18
¹⁄₂
”
(D) 20”
(E) 9”
(F) 15”
Connector heat shields
(686 mm)
(330 mm) (470 mm)
(508 mm)
(229 mm)
(381 mm)
and lue collar shield
Single wall with no
(A) 33”
(B) 23”
(C) 26
¹⁄₂
”
(D) 20”
(E) 17”
(F) 21
¹⁄₂
”
heat shields
(838 mm)
(584 mm) (673 mm)
(508 mm)
(432 mm)
(546 mm)
UNPROTECTED SURFACES
PROTECTED SURFACES
Corner
Corner
Parallel Installations
Installations Parallel Installations
Installations
ST427