DC AirCube 500 - 11
Part No 94156
2011-08-23
Service
While performing cleaning or maintenance on the machine,
the unit should be off and disconnected from the power
supply.
When the suction is reduced, due to the fi lters becoming
When the suction is reduced, due to the fi lters becoming
clogged. Th
e pre-fi lter should be changed. Turn the ”soft”
clogged. Th
e pre-fi lter should be changed. Turn the ”soft”
surface out and the ”hard” surface towards the HEPA-
surface out and the ”hard” surface towards the HEPA-
fi lter.
fi lter.
If the suction still is weak, the HEPA fi lter should be chan-
If the suction still is weak, the HEPA fi lter should be chan-
ged too.
ged too. With heavy dust loads the life of the fi lters are
shorter. Use only original spare part fi lter 4080. Use suitable
breathing protection and do the operation in a closed room.
Th
e used fi lter should be sealed in a plastic bag and disposed
of according to approved methods.
Check regularly that the electrical cable is not damaged in
any way. With replacement of the cable and contact, use
only water proof replacements.
Th
e DC AirCube 500 should be performance tested and
checked at least once per year or more frequently if subject
to intensive use.
Because this machine is used with dangerous sub-stances
maintenance is vital, worn parts should be replaced.
Never compromise the function of the DC AirCube 500,
use only original spare parts.
Th
e fan is maintenance free.
•
When light is on, it’s time for service!
Change of prefi lter:
Change of HEPA fi lter:
Montage:
Montage of prefi lter: