DC 3800a - 11
Art Nr 9467
Trouble shooting
Problem Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
The motor stops directly
Incorrect fuse.
Change to
correct circuit.
after starting.
Thermal overload not set
Electrician should adjust.
correctly.
Pump runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
The container is not fi rmly
Secure the container.
attached to the bottom of
the
cyclone.
Pump runs but poor suction.
Hole in the hose.
Change or repair hose.
Plugged
fi lter.
Clean or change fi lter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
One of the fans is turned
Start it.
off .
Machine blows dust.
Filter is perforated or has
Check the fi lters and change
come loose.
if necessary.
Abnormal sound from
Order service.
machine.