Hurricane 400 XTT / Hurricane 400 XTT – Traction
The batteries do not
provide the normal
work time
The battery poles and charging terminals are dirty
and oxidised.
Clean and grease the poles and terminals, recharge
the batteries.
The electrolyte level is low.
Top up all the elements with distilled water
as described in the instructions.
The battery charger does not work or is unsuitable.
See battery charger instructions
There are considerable differences in density
between the various elements of the battery.
Replace the damaged battery.
You are using the machine with excessive pressure
on the brushes.
Reduce pressure on the brush.
There are considerable differences in density
between the various elements of the battery.
Replace the damaged battery.
The battery discharges
too fast during use,
even though it has
been charged correctly
and when tested with a
hydrometer at the end
of recharging, it turned
out to be uniformly
charged
The battery is new and does not deliver 100%
of its expected capacity.
The battery must be “run-in” by performing 20-
30 charges and discharges to obtain maximum
performance.
The machine is being used at maximum capacity
for continuous periods and the working time is not
sufficient.
If possible, use batteries with a higher capacity
or replace the batteries with others charged
previously.
The electrolyte has evaporated and does not cover
the plates completely.
Top up all elements with distilled water until the
plates are covered then recharge the battery.
Display Alarms
Alarm
Error indicator
NAN
“Drive Lever” already pressed when the machine is turned on or after an Emergency.
SIC
Emergency button pressed
POT
Speed potentiometer fault.
MOS
Board (mosfet) short circuit.
HOT
Motor thermal cutout tripped.
LIM
Board (mosfet) thermal limitation problem.
BLT
Drive block. Appears when the battery voltage is too low and the drive is blocked.
AcS
Brush Control Fault Appears when there is a fault in the solenoid switch controlling the
brushes.
AcA
Suction control fault. Appears when there is a fault in the solenoid switch controlling
suction.
FuP
Fuse. Appears when the fuse is blown.