DANGER
Risk of explosion of the pressure tank
and pressure hoses
❯
Do not change the safety valve set-
tings.
❯
Fill the pressure tank to the cut-off pressure.
WARNING
Risk of damage to the safety valve
Risk of explosion of the pressure tank
and pressure hoses due to a defective
safety valve
❯
Do not use the safety valve to vent the
pressure tank.
❯
To open, rotate the screw of the safety valve
anti-clockwise until the valve begins to blow
off. Only allow the safety valve to blow for a
short period.
❯
Then turn the screw clockwise as far as it will
go to close the valve. The valve must now be
closed again.
9.3
Draining the condensation
water
Temperature changes during transport may
cause condensation water to accumulate in the
pressure tank. The condensation water can only
be drained from the pressurised pressure tank.
❯
Start up the unit and wait until the cut-off pres-
sure is reached.
Pressure tank
❯
At maximum tank pressure, slowly open the
condensate drain valve.
❯
Close the condensate drain valve as soon as
all of the accumulated condensation water has
been blown out.
9.4
Monitoring the unit via the
network
The following requirements must be met in order
to monitor the unit on the computer:
– Unit connected to the network
– Current monitoring software installed on the
computer
Assembly
18
5286100072L02 1909V005
EN