Page 27 from 37
9.1.3
ERROR 6
This error message can have two causes:
•
Component pressure switcher (see 10.1.6)
•
Component maximum thermostat (see 10.1.7)
9.1.4
ERROR 8
This error message is given if power is cut when the stove is in the ignition,
operating or cooling phase.
9.1.5
ERROR 9
This error message is given when no revolutions are measured by the flue fan.
There are two options:
•
The flue fan does not work
•
The fan is running. Check the encoder and encoder cable. This is the sensor
that measures the speed of the flue fan.
10
Parts
Explanation parts
10.1.1
Circuit board
The circuit board or also called motherboard controls all the components in the
heater.
10.1.2
Control panel
The control panel or display is used to operate the stove.
10.1.3
Data cable
The data cable or flatcable connects the board and the control panel.
10.1.4
Auger Motor
The auger motor is attached at the bottom of the auger or so-called worm. This
is an electric motor with a transmission to 4 or 2 revolutions.
10.1.5
Auger
This is a shaft with a spindle around it. This runs at low speeds through the
auger motor and brings up the pellets.
10.1.6
Pressure monitor
The pressure switch measures the back pressure in the outlet. If the back
pressure is too high, the switch will switch over and the stove will give a
malfunction. The auger motor will then not receive power.
Содержание Batavia T4
Страница 1: ...20 4 Manual Batavia T4 Rembrand T3 Carré T3 ...
Страница 2: ...Page 2 from 37 ...
Страница 20: ...Page 20 from 37 a Batavia T4 Figure 11 Exploded view Figure 2 Combustion Pot Figure 3 Vermiculite Lining ...
Страница 21: ...Page 21 from 37 b Rembrand T3 Figure 4 Igniter Removal Figure 5 Fan Removal Figure 1 Exploded view ...
Страница 23: ...Page 23 from 37 c Carré T3 Figure 1 Exploded view Figure 2 Combustion Pot Figure 3 Vermiculite Lining ...
Страница 31: ...Page 31 from 37 12 Electrical diagram ...