Programming
112
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
Information
For values corrected relative to the sewing field, the system will show a
correction aid in the left half of the display. The correction indicates the
direction in which the correction will take effect.
Fig. 86: Entering values using the numeric keypad (2)
Piece counter
Reset piece counter
To reset the piece counter:
1. Press the button
briefly.
The piece counter is reset to 0.
Adjusting initial piece counter value
To adjust the initial piece counter value:
1. Press and hold the button
for approx. 2 seconds.
The display switches to Edit mode.
2. Use the numeric keypad to set the desired number of pieces (0-10000).
3. Confirm with
OK
.
The display returns to the start screen.