Aligning the needle bar linkage
Service Instructions 969 - 06.0 - 03/2019
49
Fig. 34: Moving the needle bar linkage sideways
To move the needle bar linkage sideways:
1. Set the stitch length to
0
.
2. Move the handwheel into the
90°
position.
3. Loosen the screw (1).
4. Loosen the screws (2).
5. Loosen the screws (3).
6. Loosen the screw (8).
7. Move the needle bar linkage (7) sideways so that needle bar (4),
feeding foot bar (5) and presser foot bar (6) are all in a line.
8. Tighten screws (1), (2), (3), and (8).
(1)
- Screw
(2)
- Screws
(3)
- Screws
(4)
- Needle bar
(5)
- Feeding foot bar
(6)
- Presser foot bar
(7)
- Needle bar linkage
(8)
- Screw