Standard reference position of the needle bar:
–
Switch the machine on and let it move to the initial position.
–
Switch the machine off again.
Correction:
–
Loosen the screws 8 and shift the proximity switch 6 according to
the instructions.
–
Tighten the screws again.
–
Readjust the adjusting sheet, if required.
Chapter 6.3 Setting the
adjusting sheet
.
6.3
Setting the adjusting sheet
The adjusting sheet is used for the quick positioning of the needle bar
in the adjustment positions when the machine is switched off.
–
Needle bar in the centre of the needle hole (reference position)
Bolt 10 abuts on the right flank of the slotted hole.
–
Needle bar in the furthest right entry point with a throw width of 6 mm.
Bolt 10 abuts on the left flank of the slotted hole.
–
Let the machine move to the initial position (e.g. immediately after
switching on).
–
Loosen the screws 11.
–
Shift the sheet in such a way that the right flank of the slotted hole
of the sheet abuts on bolt 10 of the needle bar linkage.
–
Tighten the screws 11 again.
Note
Before adjusting the sheet the settings described in chapter 6.2 must
have been made correctly.
22
11
6
9
10
8
Содержание 540 - 100
Страница 40: ...Notes 36 ...