4.1.1
User submenu
No.
Parameter name
Symbol
Range
Description
T1.1.1
Max. speed
200 … 4000
Setting of the maximum speed in the
sewing mode.
The speed can be altered in steps of
100.
T1.1.2
Speed basting stitches
200 … 4000
Setting of the speed for the basting
stitches
T1.1.3
Move out the scissors
0 … 10
Number of stitches after which the
scissors moves out and releases the
clamped needle thread
T1.1.4
Lip tension before the
upper bartack
0 … 10
Number of stitches before the upper
bartack with the bartack tension
switched on
T1.1.5
Lip tension before the
lower bartack
0 … 10
Number of stitches before the lower
bartack with the bartack tension
switched on
T1.1.6
Lip tension before the
lip back
0 … 10
Number of stitches before the lip
back with the lip tension switched on
T1.1.7
Lip tension before the lip
there
0 … 10
Number of stitches before the lip
there with the lip tension switched
on
T1.1.8
Lip tension after the
seam beginning
0 … 10
Number of stitches after the seam
beginning after which the lip tension
is switched on.
Only valid for taper bars.
4.1.2
Submenu for soft start setting
No.
Parameter name
Symbol
Range
Description
T1.2.1
Number of stitches
0 … 10
Number of stitches of the soft start
T1.2.2
Speed
200 … max.
sewing speed
according to T1.1.1
Speed for the soft start
4.1.3
Submenu for determining the equipment
No.
Parameter name
Symbol
Range
Description
T1.3.1
Cage width
3, 4, 6, X mm
Selection of the cage width
T1.3.2
Free cage width
1,0 … 6,0 mm
Only visible if cage width X has been
selected for T1.4.1.
Enter value for cage width.
T1.3.3
Cage length
17, 22, 35, 48,
70, X mm
Selection of the cage length
T1.3.4
Free cage length
10,0 … 70,0 mm
Only visible if cage length X has
been selected for T1.4.3.
Enter value for cage length.
T1.3.5
Knife length
1,0 … 70,0 mm
Length of the knife used.
(Default-Value: 3.5 mm)
T1.3.6
Pressure monitor
0 / 1
Pressure monitor available
8
Содержание 540 - 100
Страница 40: ...Notes 36 ...