3. Table top
In case buyer will provide his own table top its drawing is
shown in supplement.
4. Machine assembly
It is described machine assembly with stand here which is
supplied in separate pieces. Otherwise use these instructions
adequate.
4.1 Stand frame assembly
A frame is assembled according to the picture.
4.2 Assembly of components on the bottom of table top and connecting to the mains
- Put down antiskid (rubber) bands on the stand frame.
- Turn the table top its underside upwards and place it on the prepared bands.
- Screw on the drawer (1) using wood screws.
- Screw on the pedal position sensor holder (2) using wood screws and the pedal position sensor thereon using screws.
- Screw on the lighting transformer (3), if any, using wood screws.
- Screw on the trimmer feeder (5), if any, using wood screws.
- Connect the wiring box (6) lead to the terminals of the network lead of the electronics box (4) of the Mini-stop (8). For doing this,
it is necessary to remove the upper metal sheet and the left-hand lateral from the electronic box.
- Screw on the box (4) of the Mini-Stop (8) electronics using wood screws.
- Screw on the wiring box (6) using wood screews.
- Connect the trimmer feed (5) to the terminals X3 in the wiring box (6).
- Connect the supply of the lighting transformer (3) (if any) to the terminals X2 in the wiring box (6).
- Screw on the knee lever with the electric switch (7) (if any), using wood screws.
- Screw on the installation ducts (9) using wood screws.
- Install the electric line of the network conductors using clamps. Place the conductors, led within the Mini-stop electronics box,
into the installation ducts.
The Mini-Stop is a device of the protection class
I
, which means that the protection against the dangerous contact of lifeless
parts is ensured by means of a protective conductor. The Mini-Stop is destined to be connected to an earthed alternating mains
with the voltage from
190 to 240 V 50/60 Hz.
The connection thereof to the mains may be done only by means of a multipolar
plug with a protective contact. No fixed connection is permitted. Mind the uniform distribution of the power in the three-phase
mains. On every
16 A
protected phase only 3 Mini-Stops may be connected, to avoid the overload of the medium conductor (N).
The MINI-STOP may be operated only with the protective conductor connected to a functional protective system
complying with all local regulations and provisions with regard to avoiding accidents of persons owing to electric
current or fire. This protection should not be cancelled e. g. by any extending cord without protective conductor.