57363_Mounting_SeWa_Starckf_WWC_US/20.06.1
5
en
Position of electrical / water connection
300-
1000
11
3/4“
- 39
3/8“
55
90
90
IG 1/
2”
100
180
135
3
1/2”
3
1/2”
7
1/8”
2
1/8”
3
7/8”
5
3/8”
Set the height of the toilet based on the position of the drain
according to the technical drawing of the toilet.
Pre-installation
DANGER
Risk of fatal electric shock
> Disconnect electrical components from the power supply
before the installation.
> Check that all components are de-energised.
> Prevent the power supply from being switched on
accidentally by third parties.
> Ensure that there is no damage to the power supply cable.
> Lay a permanent power supply line which must be on a
separate circuit:
> Observe the position of the electrical connection
> Leave at least 800 mm (31½ ") of feed cable exposed
> Install circuit breaker
> If the product itself does not have electrical leakage
protection function, it must be installed in circuit where
there is leakage protection device installed.
> Means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules and having a
contact separation in all poles that provide full disconnection
under overvoltage category III conditions.
Rated voltage
100 – 120 V 50 – 60 Hz
Rated power
1080 W
Circuit breaker
I
N
= min. 15 A
RCD
I
N
= 30 mA
Protection degree
IP X4
Protection class
1
Pre-installation
> Install the water connection and water outlet in the specified
areas.
WARNING
Health risk and potential product
damage!
> Supply the product with tap water from the main water
system only.
> Do not connect any waste water, grey water, industrial water,
sea water or other untreated or semi-treated water.
NOTICE
Product damage due to limescale build-up
In regions with hard water, limescale build-up can impair the
performance of the product.
> Check the water quality in your region. Duravit recommends
the installation of a water softener with water hardness
≥ 14° dH (2.5 mmol/l).
5
Connecting the water
NOTICE
Avoiding any malfunctions.
> The new hose-sets supplied with the appliance are to be
used and old hose-sets should not be reused.
Cold water
DN15 (½ ")
Water pressure
0.07 – 0.75 MPa (10 – 109 psi)
Water hardness
max. 2.4 mmol/l (240 ppm)
Содержание 251009 20 92
Страница 2: ...2 57363_Mounting_SeWa_Starckf_WWC_US 20 06 1 ...
Страница 10: ...10 57363_Mounting_SeWa_Starckf_WWC_US 20 06 1 251009 20 92 ...
Страница 12: ...1 2 16 15 14 13 ...
Страница 13: ...57363_Mounting_SeWa_Starckf_WWC_US 20 06 1 13 ...
Страница 14: ...14 57363_Mounting_SeWa_Starckf_WWC_US 20 06 1 ...
Страница 15: ...57363_Mounting_SeWa_Starckf_WWC_US 20 06 1 15 ...