MK3A HASP & STAPLE

 

Using seven rivets attach hasp to 
Left Hand Door and the staple to the 
Right Hand Door as shown.

 

RAISED FLOOR MODIFICATION

 

For  sheds  being  placed  on  a  purpose  built  floor, 
(concrete,  cobbles,  ply  etc.),  the  Wall  Sheets  will  pro-
trude  20mm  below  the  Base  Plate.  This  will  stop  water 
flowing in between the Base Plate and Floor.

 

 

The  Floor  should  be  made  15mm  smaller  than  Base 
Size.

 

 

Note:

 

Although  it  is  not  essential,  fitting  Damp  Proof 
Course in between the Base Plate and the Floor 
will give added protection against moisture.

 

CLEAN UP

 

• 

Remove all swarf

 

(drill filings) with a soft brush or rag.

 

• 

Hose down roof and walls thoroughly.

 

• 

For Coloursteel sheds use touch

-

up paint provided on all nail heads, rivets and exposed cuts.

 

15

 

Содержание MK3A

Страница 1: ...Quality Built In ASSEMBLY INSTRUCTIONS MK3A BASE SIZE 3380mm x 2545mm...

Страница 2: ...hecklist If you are making your own floor refer to Raised Base Plate section now Do not attempt to build your shed in high winds Beware of sharp edges Protect your eyes and ears Use electric tools wit...

Страница 3: ...Fixed Window Frame Glaze Beads Glass Louvre Window Frame Glass Over Panel Window Hardware Pack 2 830m 1 390m 1 390m 0 350m 0 900m 1 Roof Sheets Flat Roof Sheet Clear Roof Panel Pressed Capping Sheet...

Страница 4: ...785 1630 3380 45 45 45 FRONT WALL 883 1900 or 1870 for Raised Base Plate only 45 45 45 1622 1622 3380 45 45 45 1900 or 1870 for Raised Base Plate only BACK WALL 883 YELLOW YELLOW YELLOW YELLOW YELLOW...

Страница 5: ...timber from the packaging may be used to tem porarily brace the frame before rolling it over Position 1 205m End Wall Nogs 883m down from Top Plate and nail in place If fitting a Kiwi Floor fit Floor...

Страница 6: ...Tack on a wall sheet means to use minimum nails hammered partly in to hold Wall Sheets in position Should a Wall Sheet need to be re positioned the nails can easily be prized out If a window is requir...

Страница 7: ...ack in place Re peat with remaining two sheets Step 4 Nailing Off Nail one 30mm Clout each side of the Rib two per Pan into the Top Plates and Bottom Plates Nail Wall Sheets to mid wall Nogs one per p...

Страница 8: ...ill holes in each corner and nail Win dow Frame to framing using 50mm nails Step 4 If the Window is in the gable end temporarily position the Over Panel above Window Frame Following the same angle as...

Страница 9: ...ED WINDOW Optional 9 Follow Steps 2 5 on page 8 MK3A DOOR JAMB CORNER FLASHINGS Step1 Fit Door Jamb Flashing 104 in between Top and Bottom Plates and hard against Stud Attach Door Jamb Flashing with t...

Страница 10: ...m Clout through Rib into the Ridge Beam At the back line up Ribs on the Roof Sheet with the Ribs on Wall Sheet Using one 50mm Clout nail through Rib into Back Top Plate Repeat at the front Note The 6...

Страница 11: ...sure sheet joins are flush at the outside edge then rivet flat sheets to pressed sheets Two rivets per join Centralise Roof at the other end and screw in place Step 4 Ensure Ridge Beam is straight the...

Страница 12: ...ntre Door Stop on the front face of the Overdoor Flashing and up against the underside of roof Pre drill holes and nail in place with 50mm nails Step 5 Clean out ALL drill filings Also make sure the W...

Страница 13: ...Rib MK3A FLOOR Step 1 Place shed in final position Check the di agonal measurements are the same and the shed is level before fitting Floor It is recommended that the shed is anchored down with either...

Страница 14: ...oor without the weather strip Slide hook onto square shaft and secure with a lock washer Hook Lock Washer Step 2 Once doors are hung position the Locking Stays so they slide into the Locking Brack ets...

Страница 15: ...Plate This will stop water flowing in between the Base Plate and Floor The Floor should be made 15mm smaller than Base Size Note Although it is not essential fitting Damp Proof Course in between the B...

Страница 16: ...rried out in accordance with instructions below Should the cladding fail to perform as specified above the liability of Riverlea Group Ltd shall in all cases be limited to replacing or repairing the d...

Отзывы: