background image

6

AC VOLTAGE

Range

Resolution

Accuracy

200V

100mV

± 1.2% of rdg ± 10 digits

600V

1V

± 1.2% of rdg ± 10 digits

Overload protection: 600V DC or RMS. AC for all ranges.

Frequency range: 40Hz to 400Hz.

Response: average responding, calibrated in rms of a sine wave.

DIODE & CONTINUITY

Range

Description

If continuity exists (about less than 1.5kΩ), the built-in buzzer will sound.

Shows the approximate forward voltage drop of the diode.

RESISTANCE

Overload protection: 250V DC or RMS, AC.

Range

Resolution

Accuracy

200Ω

0.1Ω

± 0.8% of rdg ± 3 digits

2kΩ

± 0.8% of rdg ± 2 digits

20kΩ

10Ω

± 0.8% of rdg ± 2 digits

200kΩ

100Ω

± 0.8% of rdg ± 2 digits

2MΩ

1kΩ

± 1.0% of rdg ± 2 digits

Maximum open circuit voltage: 3.2V

Overload protection: 250V DC or RMS, AC for all ranges.

TRANSISTOR hFE TEST (0-1000)

Range

Test Range

Test Current

Test Voltage

NPN & PNP

0-1000

lb = 10µA

Vce = 3V

OPERATION - DC VOLTAGE MEASUREMENT

• 

Connect the red test lead to the “VΩmA” jack and the black lead to the “COM” 

jack.

• 

Set the rotary switch at the desired DCV position. If the voltage to be measured is 

not known beforehand, set the range switch at the highest range position and then 

reduce it until a satisfactory resolution is obtained.

• 

Connect the test leads across the source or load being measured.

• 

Read the voltage value on the LCD display along with the polarity of the red lead 

connection.

Содержание D03126

Страница 1: ...1 MODEL D03126 Digital Multimeter with Backlight...

Страница 2: ...ge 5 DC Current 6 AC Voltage 6 Diode Continuity 6 Resistance 6 Transistor hFE Test 0 1000 6 Operation DC Voltage Measurement 7 Operation DC Current Measurement 7 Operation AC Current Measurement 7 Ope...

Страница 3: ...s from the circuit under test When measuring a TV set or switching power supply watch out for pulses in the circuit that may damage the meter Before working with and measuring voltages higher than 60V...

Страница 4: ...ed to select functions and desired ranges as well as turn the meter on or off 4 V mA jack plug in the connector for red positive test lead for voltage resistance and current except 10A measurements 5...

Страница 5: ...38mm x 69mm x 31mm Weight Approx 170g Accuracy is specified for a period of one year after calibration and at 18 to 28 C 64 F to 82 F with relative humidity to 80 DC VOLTAGE Range Resolution Accuracy...

Страница 6: ...8 of rdg 2 digits 200k 100 0 8 of rdg 2 digits 2M 1k 1 0 of rdg 2 digits Maximum open circuit voltage 3 2V Overload protection 250V DC or RMS AC for all ranges TRANSISTOR hFE TEST 0 1000 Range Test Ra...

Страница 7: ...s positive Set the rotary switch at the desired range position Connect the test leads across the resistor to be measured and read the LCD If the resistance being measured is connected to a circuit tur...

Страница 8: ...cation Be careful to observe the battery polarity Never use the meter unless the back cover is in place and securely fastened CLEANING Use a soft clean dry cloth to clean the meter Do not use any chem...

Отзывы: