OPERATION - AUDIBLE CONTINUITY TEST

• 

Connect the red test lead to the “VΩmA” jack and the black test lead to the “COM” 

jack.

• 

Set the range switch to “      ” position.

• 

Connect the test leads to the two points of the circuit to be tested. If continuity 

exists, the built-in buzzer will sound.

BATTERY & FUSE REPLACEMENT

• 

If the “       ” symbol appears on the display it indicates that the battery shouid be 

replaced.

• 

To replace a battery and fuse (200mA/250V) remove the two screws in the bottom 

of the case. 

• 

Before opening the case, always disconnect the test leads from all energised 

circuits.

• 

Remove the old fuse or battery and replace it with a new one of the same 

specification.

• 

Be careful to observe the battery polarity.

• 

Never use the meter unless the back cover is in place and securely fastened.

CLEANING

• 

Use a soft, clean, dry cloth to clean the meter.

• 

Do not use any chemicals, abrasives or solvents that may damage the meter.

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF 

ELECTRICAL & ELECTRONIC EQUIPMENT.

This symbol indicate that separate collection of Waste Electrical and 

Electronic Equipment (WEEE) or waste batteries is required. Do not dispose 

of these items with general household waste. Separate for the treatment, 

recovery and recycling of the materials used. Waste batteries can be 

returned to any waste battery recycling point which are provided by most 

battery retailers. Contact your local authority for details of the battery and 

WEEE recycling schemes available in your area.

Made in China. PR2 9PP

V 1.0

Содержание D03126

Страница 1: ...1 MODEL D03126 Digital Multimeter with Backlight...

Страница 2: ...ge 5 DC Current 6 AC Voltage 6 Diode Continuity 6 Resistance 6 Transistor hFE Test 0 1000 6 Operation DC Voltage Measurement 7 Operation DC Current Measurement 7 Operation AC Current Measurement 7 Ope...

Страница 3: ...s from the circuit under test When measuring a TV set or switching power supply watch out for pulses in the circuit that may damage the meter Before working with and measuring voltages higher than 60V...

Страница 4: ...ed to select functions and desired ranges as well as turn the meter on or off 4 V mA jack plug in the connector for red positive test lead for voltage resistance and current except 10A measurements 5...

Страница 5: ...38mm x 69mm x 31mm Weight Approx 170g Accuracy is specified for a period of one year after calibration and at 18 to 28 C 64 F to 82 F with relative humidity to 80 DC VOLTAGE Range Resolution Accuracy...

Страница 6: ...8 of rdg 2 digits 200k 100 0 8 of rdg 2 digits 2M 1k 1 0 of rdg 2 digits Maximum open circuit voltage 3 2V Overload protection 250V DC or RMS AC for all ranges TRANSISTOR hFE TEST 0 1000 Range Test Ra...

Страница 7: ...s positive Set the rotary switch at the desired range position Connect the test leads across the resistor to be measured and read the LCD If the resistance being measured is connected to a circuit tur...

Страница 8: ...cation Be careful to observe the battery polarity Never use the meter unless the back cover is in place and securely fastened CLEANING Use a soft clean dry cloth to clean the meter Do not use any chem...

Отзывы: