6.9 Trouble shooting guide

Improper installation will create an electrical hazard, which could result in death or serious injury to 

pool users, installers, or others due to electrical shock, and may also cause damage to property.

DO NOT attempt to make any adjustments inside the heater. 

Turn off power to the unit prior to attempt service or repair.

Keep your hands and hair clear of the fan blades to avoid injury.

If you are not familiar with the pool filtering system and heater:

- Do not attempt to adjust or service without consulting your dealer, professional pool or air conditioning 

contractor.

- Read the entire installation and users guide before attempting to use, service or adjust the heater or pool 

filtering system

- Do not start the heat pump until 24 hours after installation to avoid damaging the compressor.

Problem

Cause

Solution

Heat pump not running

1. No electricity

1. Switch on the electrical power

2. Unit not turned on

2. Switch on the heat pump

3. Wrong temperature setting

3. Adjust the temperature setting

4. Time delay still activated

4. Wait 3 min for unit to start

5. Air temperature below 4°C

5. Wait until temperature has risen

6. Other

6. See ‘error messages’

Insufficient heating

1. Obstacles blocking air flow

1. Remove obstacles

2. Ice on the evaporator

2. Pump will try to defrost itself

Содержание Sun Spring

Страница 1: ...Manual SUN05 SUN08 SUN12 Sun Spring...

Страница 2: ...d use 6 1 Before operation 6 2 Initial startup 6 3 General interface 6 4 Parameter interface 6 5 Parameter list 6 6 Error interface 6 7 Error parameter interface 6 8 Error list 6 9 Trouble shooting gu...

Страница 3: ...3 ENG Box content Manual Heat pump Sun Spring Connection kit 456mm 87mm 87mm 456mm 467mm 467mm 530mm 750mm 90mm 90mm SUN05 SUN08 SUN12 Dimensions x2...

Страница 4: ...ontroller Colour LCD Nominal Running current A 3 1 5 1 Max Current A 5 7 RCD Rated current A 10 EU UK SWISS 10 EU UK SWISS RCD Leakage current mA 30 Condensor Titanium Heat Exchanger NoFrost Compresso...

Страница 5: ...30V 50Hz 1 Phase Electronic Controller Colour LCD Nominal Running current A 9 Max Current A 12 RCD Rated current A 16 EU SWISS 13 UK RCD Leakage current mA 30 Condensor Titanium Heat Exchanger NoFrost...

Страница 6: ...in order to avoid a hazard 10 Always make sure the water connections of the heat pump are properly locked before you start using the machine 11 Never insert objects directly into the fan as this will...

Страница 7: ...2 Put the heat pump on a flat solid base Tilting the heat pump for max 3 is allowed Install silent blocks in order to avoid vibrations and noise All feeding of water treatment to the pool water has t...

Страница 8: ...ns for connecting the water pipes as shown below 1 1 1 1 1 2 2 2 2 3 4 5 6 3 4 2 5 6 1 Custom thread to connect part 2 2 Custom thread to connect part 1 BSP G1 1 2 straight external pipe thread 3 Hose...

Страница 9: ...ug the RCD into a fixed socket 2 Press the RESET button The indicator should be ON 3 Press the TEST button The indicator should be OFF 4 Press the RESET button again to start using the heat pump 4 4 E...

Страница 10: ...at the water is condensation is to shut off the unit and keep the pool pump running If the water stops running out of the base pan it is condensation AN EVEN QUICKER WAY IS TO TEST THE DRAIN WATER FOR...

Страница 11: ...ter the parameter menu by pushing the up and down button simultaneously 2 Go to the fahrenheit parameter P02 by pressing up down buttons 3 Press the on off button to enter the parameter set mode 4 Adj...

Страница 12: ...o stop the heat pump OFF will appear on the display UP Press to increase desired temperature Any changes will be saved automatically Down Press to reduce desired temperature Any changes will we be sav...

Страница 13: ...when you scroll through the list of parameters When the ON OFF has been pushed it will be visible and the selected parameter can be changed Up Scroll up through the list of parameters Edit the value...

Страница 14: ...2 5 PPS PASSWORD P8 10 0 PPS PASSWORD P9 0 5 PPS PASSWORD P10 10 0 PPS PASSWORD P11 5 0 PPS PASSWORD TA Ambient temperature Value of the ambient temperature TIN Water in temperature Value of the water...

Страница 15: ...sensor error Liquid line temperature sensor error Water inlet temperature sensor error By pressing UP DOWN simultaneously the Error parameter interface we ll be entered Here it is shown which specifi...

Страница 16: ...e RCD If the pump still shows the error after that please contact your service centre or similarly qualified person Condensor water inlet temperature error The water inlet temperature sensor is broken...

Страница 17: ...professional pool or air conditioning contractor Read the entire installation and users guide before attempting to use service or adjust the heater or pool filtering system Do not start the heat pump...

Страница 18: ...rface diagram Sun Spring FUSE RY1 RY2 TRANSFORMER Y G Y G RED BLU BLK BLU C C L N RED ORG BLK WHI S COMP FAN R C DISPLAY 230VAC POWER SUPPLY Te Evap Temp sensor Tc Cond Temp sensor Tin Water In Temp s...

Страница 19: ...19 ENG 7 2 Piping diagram and definition Sun Spring Condensor Strainer Capillary Evaporator Compressor Win Tamb Tliq Tevap...

Страница 20: ...s been stored for a long time perform the following steps when re starting the system 1 Inspect the system for any debris or damage to the case 2 Clean the evaporator fins with a soft cloth if necessa...

Страница 21: ...central point for recycling of electrical and electronic domestic applications By doing this you will help to preserve the environment 11 Service If you need service or information or if you have a p...

Страница 22: ...ater flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product 8 Chemical contamination of combustion air...

Страница 23: ...23 ENG...

Страница 24: ...stems bvba Dooren 72 1785 Merchtem Belgium Tel 32 2 461 02 53 Fax 32 2 706 59 60 www duratech be info propulsionsystems be We reserve the rights to change all or part of the contents of this document...

Отзывы: