5. Be aware of
5.1 Heat loss
The longer the distance from the pool, the greater the heat loss from the tubing. It is therefore
recommended to place the pump as close to the pool as possible.
5.2 Condensation
As the heat pump cools down the air about 10°C, water may condense on the fins of the evaporator.
If the relative humidity is very high, this could be as much as several liters an hour. The water will
run down the fins into the base pan and drain out through the hole at the bottom of the heat pump.
Sometimes this condensation water is wrongly considered as swimming pool water. If desired the
heatpump can be fitted with a clear vinyl tube, to divert the condensation water away from the
heatpump.
TIP:
A quick way to verify that the water is condensation is to shut off the unit and keep the pool pump
running. If the water stops running out of the base pan, it is condensation. AN EVEN QUICKER
WAY IS TO TEST THE DRAIN WATER FOR CHLORINE - if there is no chlorine present, then it’s
condensation.
5.3 Unobstructed space
A free area around the heat pump has to be kept clear from
any object
to get fresh air across the
evaporator. Do not obstruct the fan.
Several days will be needed to bring the temperature of the swimming pool water to its desired water
temperature, depending on the initial water temperature, ambient and pool volume.
A good pool cover and insulation of the tubing to and from the swimming pool and heat pump can reduce the
warming up time considerably.
Check regularly that the drainage is not clogged and that no condensation water remains in the heatpump.
blow out:
3000mm
inlet air:
500mm
connection
area:1000mm
inlet air:
500mm
inlet air:
500mm