![Duratech Sun Spring Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/duratech/sun-spring/sun-spring_manual_2541483012.webp)
12
6.3 General interface
The heat pump can be turned on or off with the ON/OFF button.
1. When OFF the display is showing the following information:
- The indication ‘OFF’ at the location of the pool water temperature
- The temperature wanted for heating
- Eventual error messages
2. When ON the display is showing the following information:
- The temperature wanted for heating
- The pool water temperature
- The indication ‘Heating’ when the unit is heating the water
- A graphical representation of the water flow: the flow bar
The heat pumps has it best performance when the flow bar is in the green zone. The graph is only
valid after at least 15 minutes of operation, as the operation of the pump takes some time to reach
its optimum working balance.
ON/OFF:
Press the ON/OFF button to start the heat pump. The current water temperature
will appear and the heat pump will start automacitally. The heat pump won’t start
when the desired water temperature is reached. Meanwhile the current water
temperature is shown on the display.
Press the ON/OFF button to stop the heat pump.
OFF
will appear on the display.
UP:
Press to increase desired
temperature. Any changes
will be saved automatically.
Down:
Press to reduce desired
temperature. Any
changes will we be saved
automatically.
Set temperature:
Shows the desired temperature of the swimming pool. Your heat
pump will stop heating when desired temperature is reached. The
heat pump will start automatically when the water temperature
drops below set point.
Low air temperature:
The heat pump stops working at 3,5°C
and will restart automatically when the
ambient temerature is above 4°C.
Flow bar:
Indicates the amount of
water flow going through
the heat pump.
High air temperature:
The heat pump will stop
working when the ambient
temperature
is
above
40,5°C. and will restart
automatically when the
ambient temerature is
below 40°C.
Low flow:
The heat pumps stops
working. The amount of
water flow going through
the heat pump is too low.
The heat pump wil restart
automatically when the
water flow is restored.
Pool temperature:
Shows the temperature of
the swimming pool.
Heating:
Highlights when the heat
pump is heating.
Defrosting:
Highlights when the heat
pump is defrosting.
The flow bar is a graphical representation of the water volume through the unit.
Содержание Sun Spring
Страница 1: ...Manual SUN05 SUN08 SUN12 Sun Spring...
Страница 23: ...23 ENG...