DURASTAR.COM
14
MANUAL OPERATION (USE WITHOUT THERMOSTAT)
The manual override button is intended for testing purposes and emergency operation. Please do
not use this button unless the wired thermostat is unresponsive and it is absolutely necessary. The
unit must be turned off before manual operation.
To operate your unit manually:
1. Locate the MANUAL button on the display panel of the unit.
2. Press the MANUAL button one time to activate FORCED AUTO mode.
3. Press the MANUAL button again to activate FORCED COOLING mode.
4. Press the MANUAL button a third time to turn the unit off.
LED DISPLAY INDICATORS
The following is a list of possible indicators that may appear on the indoor unit's display panel. Not
all the display indicators may be available on the unit purchased.
Feature
Indicator
Notes
TIMER ON,
SWING, TURBO,
SILENCE
ON
Displays for 3 seconds when the TIMER ON feature is set or the
SWING, TURBO, or SILENCE feature is turned on. If the unit is off,
ON will continue to be shown if the TIMER ON feature is set.
TIMER OFF,
SWING, TURBO,
SILENCE
OF
Displays for 3 seconds when the TIMER OFF feature is set or the
SWING, TURBO, or SILENCE feature is turned off.
SELF CLEAN
SC
Displays when the SELF CLEANING feature is on.
FP
FP
Displays when the FP feature is on.
FORCED
COOLING
FC
Displays when the FORCED COOLING mode is selected with the
manual control button. See Manual Operation section.
ANTI-COLD AIR
FLOW
cF
The unit is designed not to blow cold air in HEAT mode. When
HEAT mode is selected the unit will display "cF" until the set
temperature is reached and the unit can blow warm air.
DEFROST
dF
Displays when unit is defrosting. This may last 5-10 minutes
depending on the outdoor temperature and the amount of frost
buildup on the outside unit.
Manual
Button
Display
Panel
Содержание DR1H09D09