background image

 

 

Instruction Manual 

PAT-1114 Power Units - V1.1 

www.durapac.com 

Page 4 of 15 

 

 

Do NOT

 exceed the rated capacity of the power unit or any equipment in the system. 

Burst hazard exists if connection pressure exceeds rated pressure 

 

Regularly inspect power unit, hoses and connections before each use to prevent 
unsafe conditions from developing. 

Do NOT

 use if they are damaged, altered or in 

poor condition. 

Do NOT

 operate the system with bent or damaged coupler or 

damaged threads 

 

Do NOT

 subject the power unit and its components to shock loads 

 

Use only Durapac approved accessories and components 

 

Ensure that the chosen application is stable to work on and around 

 

Do NOT

 connect to an application which can return more oil to the reservoir than the 

power unit reservoir can hold 

 

Do NOT

 connect power unit to a hydraulic system that is powered by another pump 

3.2

 

Hydraulic Hoses & Fluid Transmission Lines 

 

Avoid short runs of straight line tubing. Straight line runs do not provide for expansion 
and contraction due to pressure and/or temperature changes 

 

Ensure that the minimum bending radius is greater than 120 mm 

 

Reduce stress in tube lines. Long tubing runs should be supported by brackets or clips. 
Before operating the power unit, connections should be tightened securely and leak-
free. Over tightening can cause premature thread failure or high pressure fittings to 
burst 

 

Should a hydraulic hose ever rupture, burst or need to be disconnected, immediately 
shut off the power unit and release all pressure. Never attempt to grasp a leaking 
pressurised hose with your hands. The force of escaping hydraulic fluid can inflict 
injury 

 

Do NOT

 subject the hose to potential hazard such as fire, sharp objects, extreme heat 

or cold or heavy impact 

 

Do NOT

 allow the hose to kink, twist, curl, crush, cut or bend so tightly that the fluid 

flow within the hose is blocked or reduced. Periodically inspect the hose for wear 

 

Do NOT

 pull, position or move setup by the hose 

 

Hose material and coupler seals must be compatible with the hydraulic fluid used. 
Hoses also must not come in contact with corrosive materials such as battery acid, 
creosote-impregnated objects and wet paint. Never paint a coupler or hose 

FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY DAMAGE. 

4.0

 

Installation 

 

IMPORTANT:

 Always secure threaded port connections with high grade, non-hardening pipe 

thread sealant. Teflon tape can be used if only one layer of tape is used and it is applied 

Содержание PAT-1114

Страница 1: ...LTD 2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Air Torque Wrench Powe...

Страница 2: ...sure of your power unit s suitability for a particular application 2 0 Receiving Instructions It is recommended prior to use that an inspection be done by qualified personnel and that any missing or d...

Страница 3: ...lift a load weighing more than the capacity of the cylinder IMPORTANT If at any stage the safety related decals become hard to read these must be replaced Minimum age of the operator must be 18 years...

Страница 4: ...es Long tubing runs should be supported by brackets or clips Before operating the power unit connections should be tightened securely and leak free Over tightening can cause premature thread failure o...

Страница 5: ...and one female connector to ensure proper connection between the power unit and the wrench Figure 1 Hydraulic Connectors 4 4 Air connection connect suitable air supply to air input port Ensure that yo...

Страница 6: ...he pump Port A is a high pressure port it delivers the oil at a high pressure Whereas Port B is a low pressure port that delivers the oil at a low pressure 5 1 Prior to operation loosen the high press...

Страница 7: ...c Oil or equivalent Equipment must only be serviced by a qualified hydraulic technician For repair service contact your local Durapac authorised service centre Tighten connections as needed Use non ha...

Страница 8: ...required 6 2 2 Cycle the power unit with hydraulic torque wrench attached several times 6 2 3 Retract the hydraulic torque wrench Air will be released into the pump reservoir 6 2 4 Recheck oil level...

Страница 9: ...worn or missing in the female couplers Replace the couplers Power unit cannot reach the rated pressure Pressure is adjusted too low for the high pressure valve Check the gauge Adjust to rated value Oi...

Страница 10: ...awing Item Description Qty Item Description Qty 1 Oil reservoir 1 9 Roll cage 1 2 Bolt 1 10 Hydraulic couplers 1 3 Air motor 1 11 Regulating valve 1 4 Oil water seperator 1 12 Oil gauge 1 5 Air input...

Страница 11: ...Qty Item Description Qty 1 Oil reservoir 1 8 Pneumatic control valve 1 2 Pump 1 9 Subplate 1 3 Oil return pipe 1 10 Male elbow 1 4 Petrol pipe 1 11 Nylon tube 500mm long 1 5 Oil return pipe 1 12 Air s...

Страница 12: ...8 Pressure valve 1 9 Check valve assy 2 9 1 One way valve 1 9 2 Ring 1 9 3 O ring 1 9 4 O ring 1 9 5 Ring 1 10 Pressure valve assy 1 10 1 Pressure valve 1 10 2 Ring 1 10 3 O ring 1 10 4 O ring 1 11 F...

Страница 13: ...3 1 Valve body 1 5 1 Valve body 1 9 1 Valve body 1 3 2 Ring 1 5 2 O ring 2 9 2 O ring 1 3 3 O ring 1 5 3 O ring 1 9 3 O ring 1 3 4 O ring 1 6 Pressure gauge 1 10 Female coupler 1 3 5 Ring 1 7 Pressur...

Страница 14: ...apac com Page 14 of 15 8 5 Remote Control Item Description Part No Qty 1 Remote case ZAW1578 1 2 Air valve ZAW1579 1 3 Button ZAW1580 1 4 Circlip ZAW1581 1 Complete Assembly ZAW1577 1 Serial model and...

Страница 15: ...Instruction Manual PAT 1114 Power Units V1 1 www durapac com Page 15 of 15 9 0 Hydraulic Schematic...

Отзывы: