background image

 

 

Instruction Manual 

PAT-1114 Power Units - V1.1 

www.durapac.com 

Page 3 of 15 

 

 

 

Do NOT 

handle pressurised hoses. Escaping oil under pressure can penetrate the skin 

causing serious injury. If oil is injected under the skin, see a doctor immediately 

 

 

Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting 
device, should never be used as a load holding device. After the load has been raised 
or lowered, it must always be blocked mechanically 

 

WARNING: 

 

 

The system operating pressure must not exceed the pressure rating of the lowest 
rated component in the system. Install pressure gauges in the system to monitor 
operating pressure. It is your window to what is happening in the system 

 

 

Always wear protective gear when operating hydraulic equipment. The operator must 
take precaution against injury due to failure of the tool or work piece(s) 

 

 

Do NOT

 hold or stand directly in line with any hydraulic connections while pressurising 

 

 

Do NOT

 attempt to disconnect hydraulic connections under pressure. Release all line 

pressure before disconnecting hoses

 

 

 

All personnel must be clear before lowering load or depressurising the system

 

 

 

Do NOT

 attempt to lift a load weighing more than the capacity of the cylinder 

 

IMPORTANT: 

 

 

If at any stage, the safety related decals become hard to read, these must be replaced 

 

 

Minimum age of the operator must be 18 years. The operator must have read and 
understood all instructions, safety issues, cautions and warnings before starting to 
operate the equipment. The operator is responsible for this activity towards other 
persons 

 

 

Do NOT

 lift hydraulic equipment by the hoses or couplers. Use the carrying handle or 

other means of safe transport

 

 

 

Hydraulic equipment must only be serviced by a qualified hydraulic technician. For 
repair service, contact the Durapac authorised service centre in your area. To protect 
your warranty, use only high quality hydraulic oil

 

 

CAUTION: 

 

 

KEEP HYDRAULIC EQUIPMENT AWAY FROM FLAMES AND HEAT.

 Hydraulic fluid can 

ignite and burn. Excessive heat will soften packings and seals, resulting in fluid leaks. 
Heat also weakens hose materials and packings. For optimum performance do not 
expose equipment to temperatures of 65°C (150°F) or higher. Protect all equipment 
from weld spatter 

 

 

No alteration should be made to this device 

3.1

 

Hydraulic Power Units 

 

Ensure that the air source is 

SWITCHED OFF

 prior to connection of hoses and other 

hydraulic equipment or prior to any repairs being undertaken 

 

Do

 use a gauge or other load measuring instrument to verify load 

Содержание PAT-1114

Страница 1: ...LTD 2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Air Torque Wrench Powe...

Страница 2: ...sure of your power unit s suitability for a particular application 2 0 Receiving Instructions It is recommended prior to use that an inspection be done by qualified personnel and that any missing or d...

Страница 3: ...lift a load weighing more than the capacity of the cylinder IMPORTANT If at any stage the safety related decals become hard to read these must be replaced Minimum age of the operator must be 18 years...

Страница 4: ...es Long tubing runs should be supported by brackets or clips Before operating the power unit connections should be tightened securely and leak free Over tightening can cause premature thread failure o...

Страница 5: ...and one female connector to ensure proper connection between the power unit and the wrench Figure 1 Hydraulic Connectors 4 4 Air connection connect suitable air supply to air input port Ensure that yo...

Страница 6: ...he pump Port A is a high pressure port it delivers the oil at a high pressure Whereas Port B is a low pressure port that delivers the oil at a low pressure 5 1 Prior to operation loosen the high press...

Страница 7: ...c Oil or equivalent Equipment must only be serviced by a qualified hydraulic technician For repair service contact your local Durapac authorised service centre Tighten connections as needed Use non ha...

Страница 8: ...required 6 2 2 Cycle the power unit with hydraulic torque wrench attached several times 6 2 3 Retract the hydraulic torque wrench Air will be released into the pump reservoir 6 2 4 Recheck oil level...

Страница 9: ...worn or missing in the female couplers Replace the couplers Power unit cannot reach the rated pressure Pressure is adjusted too low for the high pressure valve Check the gauge Adjust to rated value Oi...

Страница 10: ...awing Item Description Qty Item Description Qty 1 Oil reservoir 1 9 Roll cage 1 2 Bolt 1 10 Hydraulic couplers 1 3 Air motor 1 11 Regulating valve 1 4 Oil water seperator 1 12 Oil gauge 1 5 Air input...

Страница 11: ...Qty Item Description Qty 1 Oil reservoir 1 8 Pneumatic control valve 1 2 Pump 1 9 Subplate 1 3 Oil return pipe 1 10 Male elbow 1 4 Petrol pipe 1 11 Nylon tube 500mm long 1 5 Oil return pipe 1 12 Air s...

Страница 12: ...8 Pressure valve 1 9 Check valve assy 2 9 1 One way valve 1 9 2 Ring 1 9 3 O ring 1 9 4 O ring 1 9 5 Ring 1 10 Pressure valve assy 1 10 1 Pressure valve 1 10 2 Ring 1 10 3 O ring 1 10 4 O ring 1 11 F...

Страница 13: ...3 1 Valve body 1 5 1 Valve body 1 9 1 Valve body 1 3 2 Ring 1 5 2 O ring 2 9 2 O ring 1 3 3 O ring 1 5 3 O ring 1 9 3 O ring 1 3 4 O ring 1 6 Pressure gauge 1 10 Female coupler 1 3 5 Ring 1 7 Pressur...

Страница 14: ...apac com Page 14 of 15 8 5 Remote Control Item Description Part No Qty 1 Remote case ZAW1578 1 2 Air valve ZAW1579 1 3 Button ZAW1580 1 4 Circlip ZAW1581 1 Complete Assembly ZAW1577 1 Serial model and...

Страница 15: ...Instruction Manual PAT 1114 Power Units V1 1 www durapac com Page 15 of 15 9 0 Hydraulic Schematic...

Отзывы: