Instruction Manual
DPA-15R Air Hyd. Power Unit - V1.1
www.durapac.com
Page 6 of 10
determined by the operator of the equipment
Do NOT
operate a power unit that is disconnected from the application. If operated in
this condition, the hose and connections will become pressurised. This increases the
chance of a burst hazard. Damage may also occur to the power unit and its
components
5.1
Air connection - Remove plug from first or second air input port (refer figure 2) and
connect to adequate air supply. Install hex plug on unused air input port to prevent air
leakage.
Figure 2 – DPA-15R – Remote and hose
5.2
Hydraulic connection - Remove manifold plug from oil output port and connect to
suitable application using 3/8” NPT connection.
5.3
To operate power unit, press and hold on the advance button of the remote control
until the desired pressure, load or position is reached.
5.4
To retract application, simply press the retract button on the remote control.
Note -
Both air input ports use a 1/4" NPT air nipple (not included). It is recommended to
install an inline air filter upstream from the power unit to provide clean, lubricated air.
Contact your Durapac representative for the necessary accessories.
6.0
Maintenance
IMPORTANT:
Check oil level regularly
Use only good quality hydraulic fluid.
Do NOT
use brake fluid, transmission fluid,
turbine oil, motor oil, alcohol, glycerine etc. Use of anything other than good quality
hydraulic oil will void warranty and damage the power unit, hose, and application. We
recommend Durapac Hydraulic Oil or equivalent
Equipment must only be serviced by a qualified hydraulic technician. For repair service,
contact your local Durapac authorised service centre