background image

 

 

Instruction Manual 

DPA-15R Air Hyd. Power Unit - V1.1 

www.durapac.com 

Page 2 of 10 

 

 

This is a safety alert symbol. It is used to alert you to potential personal injury hazards. 
Obey all safety messages that follow this symbol to avoid injury or death 

1.0

 

Product Information 

DURAPAC – Remote Equipped Reciprocating Air Hydraulic Power Units are engineered to meet 
Industrial Standards for Performance and Safety. The DPA-15R’s unique hydraulic circuit allows the 
quick displacement of hydraulic fluid under no load conditions and easy pumping in loaded 
conditions. The remote has an advance-hold-retract button and a three metre long hand lead.  These 
air actuated power units supply compressed hydraulic fluid to a compatible single-acting cylinder, 
anywhere that 700 bar of fluid pressure is needed.  

 

Remote actuation for adv/hold/retract functions 

 

1.5 L usable oil reservoir 

 

3 position treadle for adv/hold/retract functions 

 

Dust cover protection for the release control valve 

 

Release detent function enhances productivity 

 

Convenient carry handle included 

 

Recommended air pressure range 4-12 bar 

Special skill, knowledge and training may be required for a specific task and the product may not be 
suitable for all jobs. The user must ultimately make the decision regarding suitability of the product 
for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac 
representative if you are unsure of your power unit’s suitability for a particular application. 

2.0

 

Receiving Instructions 

It is recommended prior to use that an inspection be done by qualified personnel and that any 
missing or damaged parts, decals, warning/safety labels or signs are replaced with Durapac 
authorised replacement parts only. Any power unit that appears to be damaged in any way, is worn, 
leaking or operates abnormally should be removed from service immediately until such time as 
repairs can be made. Any power unit that has been or suspected to have been subject to a shock 
load should be removed from service immediately until inspected by a Durapac authorised service 
centre. Owners and operators of this equipment should be aware that the use and subsequent 
repair of this equipment may require specialised training and knowledge. 

3.0

 

Safety 

Save these instructions. For your safety, read and understand the information contained within. The 
owner and operator should have an understanding of this product and safe operating procedures 
before attempting to use this product. Instructions and safety information should be conveyed in the 
operator's native language before use of this product is authorised. Make certain that the operator 
thoroughly understands the inherent dangers associated with the use and misuse of the product. If 
any doubt exists as to the safe and proper use of this product as outlined in this factory authorised 
manual, remove from service immediately. 

Содержание DPA-15R

Страница 1: ...2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Reciprocating Air Hydrauli...

Страница 2: ...f safety for all in the work area Contact a Durapac representative if you are unsure of your power unit s suitability for a particular application 2 0 Receiving Instructions It is recommended prior to...

Страница 3: ...re disconnecting hoses All personnel must be clear before lowering load or depressurising the system Do NOT attempt to lift a load weighing more than the capacity of the cylinder IMPORTANT If at any s...

Страница 4: ...ly shut off the power unit and release all pressure Never attempt to grasp a leaking pressurised hose with your hands The force of escaping hydraulic fluid can inflict injury Do NOT subject the hose t...

Страница 5: ...nnect the white hose into the air line coupler number 3 on the power unit and then put the other end of the white hose into the corresponding slot on the remote control Figure 1 DPA 15R 4 7 Remove air...

Страница 6: ...power unit press and hold on the advance button of the remote control until the desired pressure load or position is reached 5 4 To retract application simply press the retract button on the remote c...

Страница 7: ...ove the air vent plug located on the top plate of the reservoir 6 1 3 Use a small funnel to fill the reservoir to within 19mm 3 4 of the opening 6 1 4 Bleed air from system if necessary 6 1 5 Wipe up...

Страница 8: ...lfunctioning power unit or valve Contact a Durapac authorised service centre Repair or replace as necessary Leaking application connection Replace application connection Application responds slower th...

Страница 9: ...it V1 1 www durapac com Page 9 of 10 Note Not all components of the pump are replacement items but are illustrated as a convenient reference of location and position in the assembly sequence 8 0 Parts...

Страница 10: ...041 1 55 Air entrance base ZBN1089 1 17 O ring ZBN1001 1 56 Screw 2 18 Copper washer 6 57 Screw 1 19 Oil tank cover 1 58 Plug assembly ZBN1073 1 20 Screw ZBN1043 1 59 Compressing spring ZBN1074 1 21 S...

Отзывы: