Installation and Operation

4

975-0345-01-01

Installation and Operation

To install PowerSource 1800:

1. Plug the power cord directly into a wall outlet (not into a surge protector or 

power strip).

2. Connect your electronic devices or small household appliances to the five 

AC outlets of the PowerSource 1800.

3. Turn on the unit by pressing the Power button for at least half a second. The 

green AC Power LED confirms that the PowerSource 1800 is on and ready 

to provide backup power.
When the battery needs recharging, the LED screen flashes “CHG” 10 times, 

then the battery capacity (%) once. This pattern of flashing continues until 

the battery capacity reaches 100% and “FUL” appears on the screen.

Backup Power Feature

The unit’s five 

120 VAC

 outlets are permanently backed up by the internal battery 

when utility power is not available. To activate the AC outlets for backup 
operation, turn on the unit using the Power button. During a power outage or 

other utility problem (such as brownouts and over-voltages), PowerSource 1800 

will keep running the connected products for up to 10 hours, depending on the 
power draw of your application (see “Run Time on Typical Products” and “Run 

Time for Combinations of Products”). When utility power is restored, the unit 

automatically recharges its internal battery.

Operation Guide

WARNING: Shock Hazard

If the input plug is connected and utility power is present, the outlets will be 
energized. The front panel ON/OFF button will not turn these outlets off.

Important:

PowerSource 1800 should be used or stored in a clean, temperature-

controlled, indoor area away from direct sunlight, moisture or conductive contaminants. 

Allow a minimum of 3 inches of space around the unit for optimal ventilation.

Important:

PowerSource 1800 must be charged immediately before storage or 

use.

 This will protect the battery inside from damage and will ensure extended usage run 

time. A complete charge may take up to 15 hours when recharged from a 120 VAC wall 

outlet.

CAUTION: Equipment Damage

Do not plug surge-protected power bars into 

the unit

’s 120 VAC outlets.

Do not connect an AC power source to the 120 VAC outlets.

Do not connect the unit’s AC power cord to its 120 VAC outlets.

Important:

When connected to utility power, 

the unit 

automatically provides AC 

power from its internal battery when the utility voltage falls below 105 VAC.

Condition

LED status

Alarm status

Alarm stops sounding when…

Normal operation

: Utility power is available and unit is 

turned on. The internal battery is fully charged.

AC Power LED and Charged/Charging LED 

are solid green. Screen shows “FUL.”

None

Not applicable

Backup power

: Utility power is not available. Unit supplies 

power from its internal battery.

Battery LED is flashing amber.

One beep when the power outage 

occurs.

Utility power becomes available; unit resumes 

normal operation or when it is turned off. 

Low battery warning

: During backup power operation, the 

internal battery is close to being completely discharged.

Battery LED is flashing amber. Screen 

shows Error code E05.

Beeps once every 2 seconds.

Utility power becomes available; unit resumes 

normal operation or when it is turned off. 

Overload shutdown

: During backup power operation an AC 

outlet overload was detected.

Fault LED on. Screen shows Error code E03. One beep per second. Unit shuts down 

after 10 seconds.

Not applicable

Under-voltage shutdown

: During backup power operation 

the battery power has been completely exhausted. No power 

is available at the AC outlets.

Fault LED on. Screen shows error code E01. One beep per second. Unit shuts down 

after 10 seconds.

Not applicable. Unit starts recharging the 

internal battery when utility power is restored. 

Turn on the unit to restore normal operation.

Over-temperature warning

: During backup power 

operation, the unit is close to shutting down to protect its 

internal circuitry from high temperatures.

Fault LED on. Screen shows error code E06. Beeps once every 2 seconds.

Better ventilation to the unit is provided, or the 

unit enters over-temperature shutdown, or the 

unit is turned off.

Over-temperature shutdown

: Unit has shut down to protect 

its internal circuitry from high temperatures.

Fault LED on. Screen shows error code E04. One beep per second.

The unit is turned off or when the unit shuts 

down.

Recharging internal battery

: Unit is recharging its internal 

battery after utility power has been restored. Internal fan is 

running.

AC Power LED is green. Charged/Charging 

LED flashes amber. Screen shows “CHG” 

alternating with battery capacity (%).

No sound

Not applicable. Screen shows “FUL” when unit 

is completely charged.

Содержание PowerSource 1800

Страница 1: ...peration of this product WARNING Shock hazard Keep away from children PowerSource 1800 generates the same potentially lethal AC power as a normal household wall outlet Do not insert foreign objects in...

Страница 2: ...g space heaters and pellet stove igniters Visit www DuracellPower com for higher power solutions Precautions for Using Rechargeable Appliances Most rechargeable battery operated equipment uses a separ...

Страница 3: ...e backup power 4 LED Screen indicates charging status power draw from the PowerSource 1800 W when providing backup power or battery capacity The screen also shows error codes to aid troubleshooting 5...

Страница 4: ...utlets Important When connected to utility power the unit automatically provides AC power from its internal battery when the utility voltage falls below 105 VAC Condition LED status Alarm status Alarm...

Страница 5: ...qualified battery technician Suitable replacement batteries are Panasonic LC X1220P and EnerSys NPX 80 Power Consumption of Loads Normal Operation with Utility Power Ability to Provide Backup Power n...

Страница 6: ...rechargeable it s recyclable Battery Biz is committed to environmental responsibility and has established a program for recycling Duracell rechargeable battery related products For instructions on ho...

Страница 7: ...not turn on Battery is discharged and utility power is not available at the wall outlet Ensure power is available at the wall outlet No power available at the 120 VAC outlets AC outlet has been overl...

Страница 8: ...l 2 1 5 t h g i e W Approvals ETL Certified to UL 1778 2nd Edition and CSA C22 2 no 107 1 01 standby UPS Standards FCC Class B Quality Guarantee Battery Biz guarantees each Duracell product to be fre...

Страница 9: ...ctions accompanying this warranty This warranty does not cover any damage due to accident misuse abuse or negligence Disclaimer Of Warranty The limited warranty described herein is your sole remedy To...

Страница 10: ...10...