SSI:POL (direction of the sensor signal)
Command
Parameter
Unit
Group
SSI:POL1 X
SSI:POL2 X
x= +|-
-
IO_CONFIG
It reverses the sensor operating direction.
SSI:RES (signal resolution)
Command
Parameter
Unit
Group
SSI:RES
x
x= 100… 10000
0,01 µm
IO_CONFIG
This command defines the sensor signal resolution.
Data entry has a resolution of 10 nm (nanometres or 0,01 µm). This means that if the sensor is
1 µm resolution the value should be set to 100. This makes possible to scale rotational sensors.
Take the data from the sensor
’s
data sheet.
SSI:BITS (number of bits)
Command
Parameter
Unit
Group
SSI:BITS X
x= 8… 31
bit
IO_CONFIG
The number of data bits is set with this parameter. Take the data from the sensor
’s
data sheet.
SSI:CODE (signal coding)
Command
Parameter
Unit
Group
SSI:CODE X
x= GRAY|BIN
-
IO_CONFIG
The data coding is set with this parameter. Take the data from the sensor
’s
data sheet.
SSI:
ERRBIT (position of the “out of range” bit)
Command
Parameter
Unit
Group
SSI:ERRBIT_1 X
x= 8… 31
-
IO_CONFIG
The position of the error bit will be defined by this parameter.
Take the data from the sensor
’s
data sheet. Use 0 as default value if the error bit is not described