EWM-2SS-DAD/22E-PN
89475/119 ETM
Duplomatic MS
▪
EWM-2SS-DAD/22E-PN Start-up Manual
–
89475-PN/119 ETM --- Mar 2019
11
Influences on positioning accuracy:
The positioning accuracy is determined by the hydraulic and mechanical conditions. The right
choice of valve is therefore a decisive factor. In addition, two mutually contradictory requirements
(short position time and high accuracy) must be considered when designing the system.
The electronic limitations lie mainly in the resolution of the analogue signals, although with our
modules a resolution of < 0.01% only needs to be considered with long positions. In addition, the
linearity of the individual signal points (PLC, sensor and control module) must be considered. The
worst-case scenario is that a system-specific absolute fault occurs.
The repeat accuracy is, however, not affected by this.
V+
V+
A:A
D:A
A:B
D:B
MAX:A
MAX:B
driving out
volumetric flow
P-A
and B-T
control direction
control direction
driving in
Содержание EWM-2SS-DAD/22E-PN
Страница 1: ...89475 119 ETM EWM 2SS DAD 22E Profinet Interface Digital Card Start up manual Duplomatic MS S p A...
Страница 16: ...Start up Manual 89475 119 ETM 16 Duplomatic MS S p A All rights reserved Typical wiring...
Страница 50: ...Start up Manual 89475 119 ETM 50 Duplomatic MS S p A All rights reserved...