Subject:
DC-10 I/F Cable Connection
◆
Technical Bulletin
Technical
Bulletin
◆
◆
Technical Bulletin Technical
Bulletin
◆
REF: BK001D
The DBM-70 interface cable to the DC-10 Mini Collator, connects to the 9 way ‘D’ type socket at
the back of the collator, next to the Paper Receiving Tray.
The following modification to the DC-10 Mini is recommended to allow DBM-70 connection.
Remove the Upper and Lower External Covers Left. Remove the Paper Receiving Tray. Remove
the Motor Cover Panel. Remove the Sensor PWB Unit.
The ‘D’ Type socket at the back is fixed to a bracket. Remove the bracket fixings. This allows
the cable, ‘D’ Type socket and bracket to be re-routed through the chassis via a hole that was
behind the Sensor PWB unit. Remove the fixings of the ‘D’ Type Socket at the Front and fix the
re-routed cable, ‘D’ Type socket and bracket in its place.
Re-fit the Sensor PWB Unit, Motor Cover Panel, Paper Receiving Tray and Upper and Lower
External Covers Left.
With this connection it is not possible to connect a second DC-10 Mini Collator.
DIP Switches: With all other DIP switches turned ‘OFF’, DIP switch bank ‘C’ numbers 4 & 6 must
be switched ‘ON’.
Before running the system, the DC-10 Mini Collator must have the Slow Collating Speed function
selected.
Information only
✔
Upgrade parts to order
Free issue parts, on request
Sensor PWB Unit
Paper Receiving Tray and
Motor Cover Panel removed
‘D’ Type Socket and
Bracket with cable
re-routed
Remove the fixings of
the ‘D’ Type Socket at
the Front and fix the
re-routed cable, ‘D’
Type socket and
bracket in its place