JET VAC COMPACT
9.
BEFORE REFERRING TO THE TECHNICAL SERVICE
PROBLEM
POSSIBLE CAUSE
REMEDY
Machine does not produce steam and
Lack of power.
Make sure that the plug (26) is well inserted and that
vacuum does not work.
the main switch of the building is activated.
The red “Low Water” indicator (15)
All the water from the water tank (20) has been
Refill the water tank (20) with clean water.
lights up.
consumed.
There is no injection of detergent.
All the detergent from the detergent tank (19) has
Check the level in the detergent tank (19).
been consumed.
If necessary, refill the detergent tank (19).
Suction power is missing.
A) Lack of power to the vacuum cleaner.
A) Make sure that the switch (2) is in ON position and
that the plug (7) is well inserted into the socket (25).
B) The vacuum tube is obstructed.
B) Clean the vacuum tube and the accessory in use.
C) The vacuum drum (4) is full of water.
C) Empty the vacuum drum (4).
Steam does not come out.
A) Boiler has not reached yet the operational
A) Wait a few minutes.
pressure (light (10) is off).
B) Steam command switches (36-37) are off.
B) Switch on the steam command switches (36-37).
C) Steam command switch (36A) has not been
C) Use the steam command switch (36A) to activate
activated.
the steam flow.
Steam leaks through the connections of
Check the wear of the o-rings.
Clean and lubricate the o-rings.
the accessories.
If necessary, substitute them with the spares supplied.
Visualization of “ALL2” on the display.
Temperature exceeded the threshold, drain cap
Insert the drain cap, discharge the air inside the boiler
not inserted, boiler under pressure after the
calcium
by activating the steam switch on the handgrip.
draining.
Drops of water come out of the
At beginning of work water condenses in the
After a few minutes of use this problem will cease.
accessories.
tubes and tools due to the difference in
If it continues, proceed to the cleaning of the boiler.
temperature between steam and accessories.
Noise inside the generator.
The boiler getting cold, after about 6-7 hours
Wait the pressure stabilization (about 2-3 minutes), the
creates an internal depression which, at each
noise will disappear.
ignition, provokes some vibrations.
Accessories do not fit perfectly.
There is dirt build up in the joints and locking
Clean and lubricate the joints.
latches (38).
22
JVC 44/15
Содержание Jet Vac Compact
Страница 1: ...JET VAC COMPACT 1 Jet Vac Compact...
Страница 2: ...JET VAC COMPACT 2 JVC 44 15...
Страница 6: ...5 JVC 44 15...
Страница 9: ...7 JVC 44 15...
Страница 12: ...JET VAC COMPACT 6 TECHNICAL DRAWINGS 10 JVC 44 15...
Страница 15: ...JET VAC COMPACT 13 JVC 44 15...
Страница 18: ...15 JVC 44 15...
Страница 24: ...20 JVC 44 15...
Страница 30: ...JET VAC COMPACT NOTES 26 JVC 44 15...
Страница 31: ...JET VAC COMPACT 27 JVC 44 15...