background image

JET VAC 
COMPACT

 

 

 

8. 

MAINTENANCE  

 

8.1.  Maintenance of the boiler

 

 

ATTENTION

 

 

DESCONNECT  THE  UNIT  FROM  THE  ELECTRICAL  POWER  SUPPLY  BEFORE  CARRYING  OUT  USER 

MAINTENANCE.

 

 

ATTENTION. BURNING DANGER

 

 

The boiler cleaning must be carried out when the equipment has cooled down (i.e. switched off for 

at  least  5  hours)  -  for  this  reason  we  suggest  to  maintain  the  boiler  in  occasion  of  the  following 

use, as long as at least 5 hours have passed. Please proceed as follows:

 

 
 

The  device  is  equipped  with  a  maintenance  warning  system,  which  every  30  effective  working  hours 

displays the advice 

“C A L C” to warn the user to proceed with the boiler cleaning.

 

When  this  warning  appears  on the  display  it  is  still  possible  to  use the  unit  until  the  end  of  the  cleaning 

process; then, it will be necessary to switch the unit off by using the main switch (8) and unplugging the 

power cable (26).

 

The boiler cleaning must be carried out when the equipment has cooled down (i.e. 

switched off for at least 5 hours) - for this reason we suggest to maintain the boiler in occasion of 

the following use, as long as at least 5 hours have passed. Please proceed as follows:

 

 

Place  a  recipient  under  the  machine,  remove  the  boiler  drain  cap  (28)  and  wait  until  the  boiler  is 

completely emptied.

 

 

Clean eventual residuals from the cap with running water, check the efficiency of the gasket located on the 

bottom of the cap and, if necessary, substitute it (please contact your supplier for the spare parts); close 

the drain cap again.

 

 

Using water with hardness higher than 10 French degrees, (according to the usage of the unit, > 2 hours 

/  day)  it  is  necessary  to  use  water  treated  with  a  proper  water  softener  system,  which  can  reduce  the 

calcium  carbonate  up  to  less  than  4  French  degrees,  increasing  by  consequence  the  liability  of  the 

steam generator. (for any further details or to buy a water softener system, contact your supplier).

 

 

The cleaning of the boiler is completed, insert the power cable (26) into a suitable plug and activate the 

main switch (8), the “Power / Stand-by” switch (10) and the “Boiler” switch (12). It is recommended to 

activate also the minimum steam switch (36) on the handgrip, pressing also the safety switch (36A) to 

allow  the  outlet  of  the  air  remained  in  the  empty  boiler.  Wait  until  the  refilling  system  has  finished 

(approx. 2 minutes).

 

 

The maintenance of the boiler is completed; proceed with the using instructions as described in the 

paragraph (f) of the chapter 7.

 

 

We suggest to empty the water tank (20) completely if the machine will not be used for a long period of 

time.

 

 

 

 

 

Содержание Jet Vac Compact

Страница 1: ...JET VAC COMPACT 1 Jet Vac Compact...

Страница 2: ...JET VAC COMPACT 2 JVC 44 15...

Страница 3: ...MANUAL TO CONSULT IT LATER OR TO GIVE IT TO THE FOLLOWING OWNERS PLEASE READ THE SAFETY INSTRUCTIONS ON THIS HANDBOOK BEFORE PROCEEDING WITH THE FIRST USE EVENTUAL DAMAGES DUED TO THE CARRIAGE MUST BE...

Страница 4: ...SUITABLE FOR THE DISPOSING OF THE WASTE ELECTRIC AND ELECTRONIC EQUIPMENT BATTERIES OIL AND SIMILAR SUBSTANCES MUST BE RECYCLED IN THE PROPER RECYCLING CENTERS AND MUST NOT BE LEFT IN THE ENVIRONMENT...

Страница 5: ...is machine is equipped with two safety valves able to ensure the safety of the machine itself in case other primary control devices are inefficient due to a failure Due to the extreme importance of th...

Страница 6: ...5 JVC 44 15...

Страница 7: ...n extension cord is used the plug and socket must be of a watertight construction ATTENTION Inadequate extension cords can be dangerous The hand arm vibration data referred to this device are not ment...

Страница 8: ...with a dependable stainless steel boiler with automatic refilling system which allows it to produce a powerful and continuous supply of steam 24 24 hours JET VAC COMPACT is also equipped with a separ...

Страница 9: ...7 JVC 44 15...

Страница 10: ...50 60 Rated Power Boiler kW 3 Max Rated Power kW 3 Rated Steam Pressure kPa 600 bar 6 Permissible Steam Pressure kPa 1200 bar 12 Max Steam Rated Flow g min 97 Max Steam Rated Flow Kg h 5 9 Max temper...

Страница 11: ...m steam vacuum hose w handgrip 34 Steam plug 34A Locking latch steam plug 34B Steel rope 35 Detergent switch 35A Hot water switch optional 35B Detergent hot water switch optional 36 Steam adjustment s...

Страница 12: ...JET VAC COMPACT 6 TECHNICAL DRAWINGS 10 JVC 44 15...

Страница 13: ...JET VAC COMPACT H2O Optional KIT RADAMES 36 37A 34A 34 37 35 75 35A 37A 33 36 37 38 35 36A 43 44 38 39 OPEN 38 45 46 BLOK 78 77 38 78 47 48 79 76 38 49 80 50 11 JVC 44 15...

Страница 14: ...JET VAC COMPACT H2O Optional 36 KIT JULY 37 34A 34 35 35A 33 BLOCK 38 36 37 36A 35 43 44 OPEN 38 38 BLOCK 39 45 46 73 72 47 71 48 77 74 49 50 12 JVC 44 15...

Страница 15: ...JET VAC COMPACT 13 JVC 44 15...

Страница 16: ...JET VAC COMPACT CONTROL PANEL 9 Control panel 10 Power Stand by button 11 Power Stand by indicator 12 Boiler button 13 Boiler on indicator 14 Steam Ready indicator 15 Low Water indicator 14 JVC 44 15...

Страница 17: ...t and to consult the supplier The detergent tank has to be filled only with detergent diluted with water not with water only unless you are not using demineralized water The usage of water only not de...

Страница 18: ...15 JVC 44 15...

Страница 19: ...fter having performed the maintenance switch the device off by using the Power Stand by switch 10 press and hold for 10 seconds the Boiler switch 12 The warning C A L C will be restored Pressure visua...

Страница 20: ...etergent and hot water injection functions have to be activated at intermittence for ex 20 seconds ON 20 seconds OFF both functions have not to be used in continuous duty Detergent injection or hot wa...

Страница 21: ...t for a few seconds at a time to avoid excess liquid with the steam to spray hot water for models with the function of hot water injection please refer to what above indicated activating the switch 35...

Страница 22: ...seconds OFF both functions have not to be used in continuous duty Detergent injection or hot water injection optional is possible only if at least one steam command switch is activated and if Steam R...

Страница 23: ...e remove the boiler drain cap 28 and wait until the boiler is completely emptied Clean eventual residuals from the cap with running water check the efficiency of the gasket located on the bottom of th...

Страница 24: ...20 JVC 44 15...

Страница 25: ...VAC COMPACT models does not require any specific maintenance Always clean the drum and filter after use 8 3 Maintenance of the tools Grease occasionally joints on the extension tubes and on the access...

Страница 26: ...36 37 are off B Switch on the steam command switches 36 37 C Steam command switch 36A has not been C Use the steam command switch 36A to activate activated the steam flow Steam leaks through the conne...

Страница 27: ...e direttive conforms to the specifications of directives 2006 95 CE 2004 108 CE 2006 42 CE 2002 95 CE Per il controllo della conformit alle sopraindicate direttive sono stati seguiti i seguenti standa...

Страница 28: ...JET VAC COMPACT Ordinary maintenance procedures Generator working Frequency Notes hours of intervention 24 JVC 44 15...

Страница 29: ...JET VAC COMPACT Extraordinary maintenance procedures Generator Date of working intervention Intervention description replaced components etc hours 25 JVC 44 15...

Страница 30: ...JET VAC COMPACT NOTES 26 JVC 44 15...

Страница 31: ...JET VAC COMPACT 27 JVC 44 15...

Страница 32: ...MANUFACTURER RESERVES THE RIGHT TO BRING TECHNICAL AND STRUCTURAL IMPROVEMENTS WITHOUT PRIOR NOTICE Via dei Sassi 1 A Pescantina VR Italy Tel 39 045 6767252 Fax 39 045 6703631 E mail JVC JVC it www J...

Отзывы: