DUOVAC A10-130I Скачать руководство пользователя страница 7

7 | DOC-568_EN REV04

ORIGINAL INSTRUCTIONS

FILTRATION SYSTEM

In order to maintain good air quality in your home, the power unit is equipped with a fi ltration 
system. It consists of a permanent fi lter and an optional disposable fi ltration bag. The fi lter 
separates dust from the air. The fi lters refi ne the fi ltration process retaining extra fi ne dust 
particles, as minute as 0.1 micron (the diameter of one hair is approximately 60 microns).

P

ermanent

 f

iLter

Duovac’s fi ltration system will maintain its high performance as long as it is well looked after. 
The permanent fi lter can be machine-washed and tumble dried.

A natural protection (GREEN) against odour-causing 
bacteria, SILPURE exploits the natural power of silver in 
stopping the growth of a wide range of bacteria. It is 
recommended that the dust canister be emptied every three 
(3) months or more often depending on the use you make of 
your system.

IMPORTANT

DO NOT vacuum gypsum dust, fl our, mud, or any sludgy materials as they cake onto 

the fi lter and obstruct the fi ltration system resulting in the overheating of the 

motor and thus failure of the power unit to function properly;
If you are 

not using

 a disposable fi ltration bag in addition to the permanent fi lter, 

empty the dust canister regularly to ensure a longer-lasting life of the motor.
If you are 

using

 the disposable fi ltration bag, it should be checked / changed as 

often as you would empty the dust canister.

While emptying the power unit’s dust canister, the permanent fi lter should also be cleaned:

1� 

Unlatch the dust canister;

2� 

Wrap a plastic / paper bag around the fi lter and gently pat the fi lter to dislodge any loose 

dust into the bag.

3� 

Empty the dust canister into a garbage bag.

NOTE

»

We recommend that the permanent fi lter be deep-cleaned once a 

year;
a� 

Remove the dust from the fi lter by gently patting it into a bag as 

mentioned above;

b� 

Remove the fi lter by pulling it down;

c� 

Drop it into the washer.

d� 

Set the washer to a normal wash cycle (warm or cold water) then, 

spin dry (regular cycle) for 10 minutes;

e� 

Before replacing the fi lter, clean the inside of the fi ltration cage;

IMPORTANT

Do not turn fi lter inside out. It must be replaced over the cage on the same fabric 

side as initially mounted in the factory.

It is very important that the fi lter be slipped over the metal rim located at the top of 

the cage.  In order to prevent any dust infi ltration into the motor, the cage must be 

completely covered by the fi lter;

f� 

Clip the dust canister back onto the casing.

d

iSPOSaBLe

 

fiLtratiOn

 

Bag

In order to maximize your system’s fi ltration capabilities, all Duovac power units (except 
the SIG-200) come with a disposable fi ltration bag. See below instructions on replacing the 
disposable fi ltration bag depending on the system being used:

DISPOSABLE FILTRATION BAG

VACUUM MODEL

FILTRE-189

A10-130I
A10-260I(-NA/-EU/-CH/-UK/-CN)-ED

FILTRE-196

A10-260I(-NAEDSN/-NAEDSO)
A50
DIS
SEN
SIL
STR
SYM

The disposable fi ltration bag must be changed at least every 3 months to ensure proper 
functioning of the power unit.
To change the fi ltration bag, please proceed as follows:

1� 

Unlatch the dust canister;

2� 

Remove the disposable bag from the elbow attachment by gently pulling on both sides of 

the cardboard cuff ;

3� 

Dispose of the used bag;

4� 

Slip the new disposable fi ltration bag onto the elbow fi xture by gently pressing on both 

sides of the cardboard cuff  until it reaches the stop notch on the elbow.

IMPORTANT

The warranty will be void if non-recommended fi lters are used to repair the unit. 

Duovac recommends strongly to use only Duovac certifi ed fi lters.

MOTOR

All units are equipped with a soft-start control module and have a LED communicating the 
system status (see fi g. 5 in section 9 for more details on LED colour interpretation). When the 
LED changes to amber, it is time to make an appointment with a Duovac certifi ed technician for 
a complete check-up of the unit. This mandatory maintenance will extend the life of the unit 
and keep the warranty valid. If it is still not carried out after 20 hours of additional operating, 
the device will automatically switch off  as a safety measure.
All systems also have a mini breaker (power cut-off ) directly connected to the module which 
protects the motor against an overload and prevents overheating.

8. SYSTEM MAINTENANCE

Содержание A10-130I

Страница 1: ...EN 2000868 Conforms to UL Std 1017 Certified to CAN CSA Std C22 2 No 243 M91 CAN CSA Std C22 2 No 243 10 USER MANUAL CentralVacuum System Made in Canada DOC 568 REV04...

Страница 2: ...O BE OBSERVED AT ALL TIMES MODELS 5 INSTALLATION 5 POWER UNIT 5 MUFFLER 6 FLEXIBLE HOSE WITH ERGONOMIC HANDLE 6 LOW VOLTAGE WIRE CONNECTION 6 SYSTEM OPERATING INSTRUCTIONS 6 SYSTEM MAINTENANCE 7 FILTR...

Страница 3: ...order to avoid a hazard The removal of the plug has to be such that an operator can check from any of the points to which he has access that the plug remains removed for commercial use models Do not...

Страница 4: ...central vacuum system must be used only on dry surfaces At no time should the system be used to draw up liquids nor should it be used to vacuum wet carpets or floors 3 It is mandatory that the filtra...

Страница 5: ...to be screwed to at least 2 studs Fasten the mounting bracket to the mounting board with the provided screws 3 Concrete wall Drill the holes with a concrete drill bit Insert the provided wall anchors...

Страница 6: ...of the mu er is made of metal secure the mu er onto the metal elbow using the provided self tapping screw 4 OPTIONAL If you plan on exhausting the central vacuum outside install more piping starting f...

Страница 7: ...replacing the filter clean the inside of the filtration cage IMPORTANT Do not turn filter inside out It must be replaced over the cage on the same fabric side as initially mounted in the factory It is...

Страница 8: ...wall inlet touch the contacts which are located on the inside of the inlet with the hose wand in order to start the power unit NOTE Frame the inlet with your hands or a large enough piece of cloth su...

Страница 9: ...their needs So if you have any comments or suggestions related to our products or distributors please contact us For any inquiries E mail us at info duovac com Send us your comments to NUERA AIR INC...

Страница 10: ...elstellen PT Instru es Recicladoras Aparelhos usados cont m materiais valiosos que s o apro priados para reprocessamento N o colocar o aparelho no lixo dom stico normal mas sim descartar correctamente...

Отзывы: