14
OPERATOR TROUBLESHOOTING
PROBLEM
CORRECTIVE ACTION
Fasteners will not drive completely into wood.
Fasteners penetrate properly during normal
operation, but won't drive fully at faster speeds.
Fasteners drive too deeply into wood.
Tools skips during operation - no fasteners are
driven from time to time.
Tool operates, but no fasteners are driven.
Air leaks at cap when tool is connected to air.
Increase air pressure (do not exceed 120 psi).
Increase air
fl
ow to tool -- use larger air lines
(3/8 inch ID minimum).
Reduce air pressure.
Check magazine for proper fasteners. Magazine fol-
lower should slide freely. Clean as needed to remove
debris.
Make sure correct fasteners are being used.
only.
Use fasteners that meet
Duo-Fast
®
speci
fi
cations
Increase air
fl
ow to tool -- use larger air lines
(3/8 ID minimum).
Check magazine for proper fasteners. Fasteners
should slide freely with no follower pressure.
Increase air pressure (do not exceed 120psi).
Tighten capscrews.