background image

Top Panel

 

1. Level Control – controls the overall loudness of the amplifier.
2. Bass Control – provides 10dB of boost or cut at 87Hz.
3. Midrange Control – provides 10dB of boost or cut at 645Hz.
4. Treble Control – provides 8.5dB of boost or cut at 4.4kHz.
5. Presence Control – provides 6.5dB of boost or cut at 11.6kHz
6. Headphone Level Control – controls the loudness of the headphones only. 
Adjust after setting the overall loudness with the Level control.
7. Pre-Post EQ push-button – low position places the feed to the headphone 
amplifier and the balanced line amplifier post EQ. High position is pre-EQ. Note 
that pre/post EQ selection does not affect the signal to the speaker output jack.
8. Cabinet Simulation push-button – low position places the feed to the 
headphone amplifier and the balanced line amplifier post cabinet simulation. High 
position is pre-cabinet simulation. Note that cabinet simulation is not present at 
the speaker output jack.
9. Power Indicator – lights when AC power is present and the power switch is 
turned on.
10. Power Amp Clip/Over-Current Indicator – this is a dual-purpose indicator. 
The primary function is to warn when the power amp is 1dB away from clipping. 
The secondary function is to indicate when an over-current condition exists on 
the speaker output jack, such as a shorted speaker cable. See detailed explanation 
under “Protection Features”.
11. Pre-Amp Clip/Status Indicator – this is also a dual-purpose indicator. The 
primary function is to indicate when any portion of the preamp is within 6dB 
of clipping. See more information under “Preparing for use”. The secondary 
function is to indicate the status of the power supply/power amp module. When lit 
continuously, the module has shut itself down due to one or more fault conditions. 
See detailed explanation under “Protection Features”.

1

6

7

8

13

12

9

14

15

16

17

18

10 11

2

3

4

5

Panel Layouts, Control Functions and Input/Output Jacks

with motors such as compressors, refrigerators or air conditioners as this can 
cause high levels of unwanted noise in your sound or dips in power as motors start up.

SET UP: Place the unit on a firm, level surface. Do not plug or unplug an instrument 
or speaker while the amplifier is turned on.

HEAT AND VENTILATION: Make sure to allow space around the sides. Back and 
top for air circulation. Avoid use in extremely hot locations with direct exposure to 
sunlight or placement near heating equipment. Avoid use in moist or high humidity 
areas. Do not block fan opening or vent holes on the side. Allow for adequate air 
flow and do not place coats or blankets over the amplifier.

3

Содержание POWERSTAGE 200

Страница 1: ...POWERSTAGE 200 User Manual ...

Страница 2: ...fire or electric shock do not expose this equipment to moisture Keep this device away from sources of water such as pools bathtubs and sinks Do not expose to rain dripping splashing water or sprayed liquids Do not place objects filled with liquids on the top 4 Unplug from power source before cleaning Clean only with dry cloth 5 This product requires ventilation to operate properly Do not block the...

Страница 3: ...s a Class B product based on the standard of the VCCI Council If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual This device been tested and found to comply with Industry Canada ICES 003 Issue 6 2016 This device complies with CAN ICES 3B NMB 3B This device has been tested an...

Страница 4: ... function is to indicate when an over current condition exists on the speaker output jack such as a shorted speaker cable See detailed explanation under Protection Features 11 Pre Amp Clip Status Indicator this is also a dual purpose indicator The primary function is to indicate when any portion of the preamp is within 6dB of clipping See more information under Preparing for use The secondary func...

Страница 5: ...aling less than 4Ω CONNECTINPUTSIGNALLINES Usehigh quality shieldedcableand phoneplugs PREPARING FOR USE Turn Level control down Connect AC cord Observe all precautions noted in safety information Actuate power switch The two Red LEDS will light for a few seconds and then the Blue power LED will light indicating that the amplifier is ready to use If either or both Red LEDs remain lit turn power of...

Страница 6: ...can be caused by the following Lack of air circulation around amplifier Blocked vents Blocked or stopped cooling fan Excessively high ambient temperatures Heavy loading of output low impedance loads coupled with high power demand Combinations of any or all the above PREAMP CLIP STATUS INDICATOR This LED also serves multiple purposes indicating the following Preamp voltage clip warning the LED will...

Страница 7: ...bient Operating Temperature 0 to 50 C Relative Humidity 85 non condensing Altitude operating 2000m 6500 ft Weight 2 87 lbs Limited Warranty Seymour Duncan offers the original purchaser a one year limited warranty on both labor and materials from the day this product is purchased We will repair or replace this product at our option if it fails due to faulty workmanship or materials during this peri...

Страница 8: ...or the most up to date info and sound samples RevB ADDRESS 5427 Hollister Ave Santa Barbara CA 93111 CONTACT T 805 964 9610 F 805 964 9749 SOCIAL seymourduncanpickups seymourduncanpickups seymourduncan seymourduncanchannel seymourduncan com ...