13. CAUTION – RISK OF ELECTRIC SHOCK! DO NOT OPEN! There are no 
user serviceable parts inside. Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been damaged in any way, such as 
power supply cord or plug is damaged, liquid has been spilled or objects have fallen 
into the apparatus, the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped. 

14. WARNING – Due to the potential for hot surfaces and high sound pressure 
levels, this equipment is not suitable for use in locations where children are likely 
to be present.

Compliance Statement

Note: This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC rules. These limits 
are designed to provide reasonable protection against harmful interference 
in a residential installation. This equipment generates uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment on and off, the user is 
encouraged to try and correct the interference by one or more of the following 
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

This device has been tested for and found to comply with Australia and New 
Zealand AS/NZS CISPR 32. 

This device has been tested for and found to comply with Japan VCCI V3. This 
is a Class B product based on the standard of the VCCI Council. If this is used 

near a radio or television receiver in a domestic environment, it may cause radio 
interference. Install and use the equipment according to the instruction manual.

This device been tested and found to comply with Industry Canada ICES-003 Issue 
6:2016. This device complies with CAN ICES-3B/NMB-3B.

This device has been tested and found to comply with Europe’s EMC Directive 
2014/30/EU. The standards applied were EN 55032 and EN 55035.

This device has been tested and found to comply with product safety directive EN 
62368-1 for Audio/Video, information and communication technology equipment. 
EU, AS/NZ and Japan deviations have been included in testing. 

Note: Any changes or modifications to this equipment not expressly approved by 
Seymour Duncan could void the user’s authority to operate this equipment.

Recycling Information

This symbol indicates this product is classified as Waste Electrical and Electronic 
Equipment (WEEE) in the European Union and should not be discarded with 
household waste. Other territories may vary. 

Before Using Your Amplifier

 

VERIFY YOUR AC CIRCUIT VOLTAGE AND CAPACITY: This amplifier is designed 
to accommodate line voltages from 100 to 240VAC, 50/60Hz. Connection to 
voltages outside this range my cause erratic operation or result in irreparable 
damage to the unit. The warranty does not cover damage caused by connection 
to voltages below 100VC or above 240VAC. There are no user serviceable parts 
inside the chassis. Do not attempt to open the product or service it yourself.

Under maximum load conditions this amplifier may require heavy current draw. 
To ensure proper performance and avoid potential safety hazards, connect only to 
circuits that can provide a minimum of 15 amps of current. Avoid connecting to the 
same circuit as other high-current consumers such as heating devices, microwave 
ovens and high-wattage lighting as this may cause circuit breakers or fuses to 
blow. Avoid connecting any audio equipment to the same circuit as equipment 

2

Содержание POWERSTAGE 200

Страница 1: ...POWERSTAGE 200 User Manual ...

Страница 2: ...fire or electric shock do not expose this equipment to moisture Keep this device away from sources of water such as pools bathtubs and sinks Do not expose to rain dripping splashing water or sprayed liquids Do not place objects filled with liquids on the top 4 Unplug from power source before cleaning Clean only with dry cloth 5 This product requires ventilation to operate properly Do not block the...

Страница 3: ...s a Class B product based on the standard of the VCCI Council If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual This device been tested and found to comply with Industry Canada ICES 003 Issue 6 2016 This device complies with CAN ICES 3B NMB 3B This device has been tested an...

Страница 4: ... function is to indicate when an over current condition exists on the speaker output jack such as a shorted speaker cable See detailed explanation under Protection Features 11 Pre Amp Clip Status Indicator this is also a dual purpose indicator The primary function is to indicate when any portion of the preamp is within 6dB of clipping See more information under Preparing for use The secondary func...

Страница 5: ...aling less than 4Ω CONNECTINPUTSIGNALLINES Usehigh quality shieldedcableand phoneplugs PREPARING FOR USE Turn Level control down Connect AC cord Observe all precautions noted in safety information Actuate power switch The two Red LEDS will light for a few seconds and then the Blue power LED will light indicating that the amplifier is ready to use If either or both Red LEDs remain lit turn power of...

Страница 6: ...can be caused by the following Lack of air circulation around amplifier Blocked vents Blocked or stopped cooling fan Excessively high ambient temperatures Heavy loading of output low impedance loads coupled with high power demand Combinations of any or all the above PREAMP CLIP STATUS INDICATOR This LED also serves multiple purposes indicating the following Preamp voltage clip warning the LED will...

Страница 7: ...bient Operating Temperature 0 to 50 C Relative Humidity 85 non condensing Altitude operating 2000m 6500 ft Weight 2 87 lbs Limited Warranty Seymour Duncan offers the original purchaser a one year limited warranty on both labor and materials from the day this product is purchased We will repair or replace this product at our option if it fails due to faulty workmanship or materials during this peri...

Страница 8: ...or the most up to date info and sound samples RevB ADDRESS 5427 Hollister Ave Santa Barbara CA 93111 CONTACT T 805 964 9610 F 805 964 9749 SOCIAL seymourduncanpickups seymourduncanpickups seymourduncan seymourduncanchannel seymourduncan com ...