www.factorybuysdirect.com
23
HSE-MAN-013
Problem
Possible Cause
Corrective Action
When ignitor button is
pressed in, there is no
spark at ODS/pilot
1. Ignitor electrode is posi-
tioned wrong. Ignitor elec-
trode is broken.
2. Ignitor electrode is not con-
nected to ignitor cable.
3. Ignitor cable is pinched or
wet.
4 Broken ignitor cable.
5. Bad piezo ignitor.
6. Low battery.
1. Replace electrode.
2. Replace ignitor cable
3. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry.
4. Replace ignitor cable.
5. Replace piezo ignitor.
6. Replace battery.
TROUBLESHOOTING
NG
Figure 25 - Gas Regulator Pressure
Switch
Pressure
Switch
Set Screw
Pressure Switch
When using natural gas (NG), there is a
pressure switch that acts to turn off the gas
flow to the pilot if the inlet pressure exceeds
9.5" WC. This is to prevent the operation of
the unit on the wrong gas (propane/LP). If your
natural gas supply exceeds 9.5" WC the unit
will not operate. Either contact your gas sup-
plier to check and adjust the inlet pressure or
a qualified service technician can bypass the
pressure switch.
Before attempting to bypass the pressure
switch, make sure the type of gas being used
is correct. Check to make sure the connection
fitting is in the correct inlet on the regulator.
Refer to
Connecting to Gas Supply
, page 12.
Only a qualified installer should bypass the
pressure switch. To bypass the pressure
switch locate the set screw on the regulator.
Use a small flat bladed screw driver to turn the
set screw counterclockwise 2 turns. This will
bypass the pressure switch function.
Problem
Possible Cause
Corrective Action
Using natural gas and
pilot will not light.
Inlet pressure exceeds
9.5" WC.
Bypass pressure switch. See
instructions below.
The entire gas delivery piping including con-
nections inside the heater should be leak
tested by the qualified installer. After leak
testing the qualified installer should light the
appliance. Refer to the correct flame pattern
as illustrated on page 20. All flame patterns
should be safely inside the product. If for any
reason they are not, stop use of the appliance
and call for repairs.