10
Installation and Operation of:
DUKE TSC3 Proofer Oven with Touch Screen Controls
INSTALLATION
UNPACKING UNIT
Inspect the shipping carton and/or container,
carefully noting any exterior damage on the
delivery receipt; also note any damage not evident
on the outside of the shipping container (concealed
damage). Contact the carrier immediately and file a
damage claim with them. Save all packing materials
when filing a claim. Freight damage claims are the
responsibility of the purchaser and are not covered
by the warranty.
• Follow the instructions on the Carton Box for
unpacking the unit.
• Inspect unit for damage such as, broken glass,
etc.
• Report any dents or breakage to source of
purchase immediately.
• Do not attempt to use unit if damaged.
• Remove all materials from unit interior.
• If unit has been stored in extremely cold area,
wait a few hours before connecting power.
UNIT PLACEMENT
• Do not install unit next to source of heat, such
as deep fryer, etc.
• Install unit on level surface floor.
• Minimum Clearance of 6" (152mm) must
be maintained between the unit and any
combustible substance.
• Either side of the unit must remain open for
proper airflow for electrical component cooling.
The rear of the unit and one side may be
installed without clearance.
ELECTRICAL AND SUPPLY CONNECTIONS
Connection of the unit to the mains supply
MUST
be performed by an authorized person
in accordance with codes, standards, and laws
governing the installation site using properly rated
all poles mains protection, full disconnection under
over voltage category III, safety ground earthing,
and shall be a minimum of 48" (1.2 meter) long to
allow the equipment to be moved for cleaning.
USA and non-EU Countries must use flexible
conduit within variances that may be required by
local electric codes or regulations.
All International installations must use IEC 60245
IEC 66, HO7RN-F, minimum 5G 2,5mm, 5G4.0mm
maximum flexible cordage.
For 1~ appliances use minimum 3G 4.0mm, 3G
6.0mm maximum flexible cordage.
The Mains Supply safety / earth ground wire must
be longer than mains conductors at the unit's
interconnections to prevent stress under pull.
Contact Duke for service of IVS (Integrated
Ventilation System) HO5RN supply interconnection.
EXTERNAL EQUIPOTENTIAL
Terminal provides a connection for bonding to
equipment enclosure.
WATER SUPPLY CONNECTION
This equipment must be installed in accordance
with all applicable federal, state, and/or local
plumbing codes having jurisdiction.
The water inlet utilizes ¼” (6.35mm), OD plastic
tubing. Install the tubing in a manner to ensure
there are no kinks, strains, or tight bends. Leave
sufficient length to allow unit movement for service
and cleaning.
The tubing should be cut square and be free of any
deformations at the connection points. All burrs
and sharp edges should be removed for proper
connection.
Insert the tubing through the compression fitting
with the threads pointing towards the end of the
tubing.
Push the tubing into the fitting as far as it will go
and tighten the nut with a ½” (12.7mm), wrench.
Do not over-tighten the nut. If leaks occur, further
tighten the fitting until the leakage stops.
ELECTRICAL SHOCK HAZARD UNIT MUST BE
SAFETY GROUNDED, EARTHED.
DO NOT MODIFY OR DEFEAT ELECTRICAL
CONNECTIONS