IMPORTANT SAFETY INSTRUCTIONS

In  addition  to  the  warnings  and  cautions  in  this 

manual,  use  the  following  guidelines  for  safe  operation 

of  the  unit.

•  Read all instructions before using equipment.

•  For your safety, the equipment is furnished with a properly 

grounded cord connector.  Do not attempt to defeat the 

grounded connector.

•  Install or locate the equipment only for its intended use as 

described in this manual.  Do not use corrosive chemicals in 

this equipment.

•  Do not operate this equipment if it has a damaged cord or 

plug, if it is not working properly, or if it has been damaged or 

dropped.

•  This equipment should be serviced by qualified personnel 

only.  Contact the nearest Duke authorized service facility for 

adjustment or repair.

•  Do not block or cover any openings on the unit.

•  Do not immerse cord or plug in water.

•  Keep cord away from heated surfaces.

•  Do not allow cord to hang over edge of table or counter.

•  Inspect glass daily for chips, cracks, or breaking.  Discard all 

food and notify manager if any chips, cracks, or broken glass 

are found.  Do not use equipment.  All glass must be in good 

condition before using equipment to hold food.

The  following  warnings  and  cautions  appear  throughout 

this  manual  and  should  be  carefully  observed.

•  Turn the unit off, disconnect the power source and allow unit 

to cool down before performing any service or maintenance on 

the unit.

•  The procedures in this manual may include the use of chemical 

products.  You must read the Material Safety Data Sheets 

before using any of these products. 

•  The unit should be grounded according to local electrical codes 

to prevent the possibility of electrical shock.  It requires a 

grounded receptacle with separate electrical lines, protected by 

fuses or circuit breaker of the proper rating.

•  Disposal of the unit must be in accordance with local 

environmental codes and/or any other applicable codes.

•  SAVE THESE INSTRUCTIONS

:

GENERAL  WARNING  -   

Indicates  information  important 

to  the  proper  operation  of  the 

equipment.  Failure  to  observe 

may  result  in  damage  to 

the  equipment  and/or  severe 

bodily  injury  or  death.

:

ELECTRICAL  WARNING  - 

Indicates  information  relating 

to  possible  shock  hazard. 

Failure  to  observe  may  result 

in  damage  to  the  equipment 

and/or  severe  bodily  injury  or 

death.

:

HOT  SURFACE  WARNING  - 

Indicates  information  important 

to  the  handling  of  equipment 

and  parts.  Failure  to  observe 

caution  could  result  in 

personal  injury

CAUTION: 

GENERAL  CAUTION  -   

Indicates  information  important 

to  the  proper  operation  of  the 

equipment.  Failure  to  observe 

may  result  in  damage  to  the 

equipment.

Содержание IRHU Series

Страница 1: ...production without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 8...

Страница 2: ...OTENTIAL EARTHING TERMINAL EXPORT ONLY 9 DIGITAL TIMERS 9 DIGITAL TIMER DISPLAYS 9 OPERATING INSTRUCTIONS 10 PROGRAMMING MODE 10 Settings 10 SETUP MODE 11 Settings 11 CARE AND CLEANING 12 CLEANING GUI...

Страница 3: ...tastetransfer Becausethecompartments aresealed nodisassemblyisrequiredforcleaningand product changes The unique design of the Duke IR Holding Unit allows theIRenergytobeprogrammedforeachcompartment Th...

Страница 4: ...gs and cautions appear throughout this manual and should be carefully observed Turn the unit off disconnect the power source and allow unit to cool down before performing any service or maintenance on...

Страница 5: ...0 230 11 7 IRHU 22XXXX 240 240 11 3 IRHU 23XXXX 208 245lbs 111 Kg 208 19 5 4050 IRHU 23XXXX 230 230 17 6 IRHU 23XXXX 240 240 16 9 IRHU 41XXXX 208 175lbs 80 Kg 208 13 2700 IRHU 41XXXX 230 230 11 7 IRHU...

Страница 6: ...7 8 835 03 mm 23 3 4 603 25 mm 15 380 31 mm 509L COOKING APPLIANCE DE CUISINE UNDERWRITERS LABORATORIES INC IN ACCORDANCE WITH NSF NO 4 1999 IHRU 23 Twist Lock Plug Schuko Plug 603 25 mm 1214 81 mm 12...

Страница 7: ...U 41 Twist Lock Plug Schuko Plug 2 1 8 53 98 mm 2 1 2 63 89 mm 29 7 8 759 mm 17 7 8 454 96 mm 1 1 8 29 91 mm 23 5 8 601 40 mm 509L LISTED APPLIANCE DE CUISINE ALSO CLASSIFIED BY UNDERWRITERS LABORATOR...

Страница 8: ...Stop Note the style of pan stop varies by model 5 4 IRHU 12 IRHU 22 IRHU 23 Rear View 4 Programming Connection Port 5 Power Cord with Strain Relief IRHU 41 FEATURES 1 2 3 IRHU 41 Front View 1 Power O...

Страница 9: ...To avoid risk of electrical shock or death this unit must be grounded and plug must not be altered EARTHING INSTRUCTIONS Grounding reduces risk of electric shock by providing an escape wire for the el...

Страница 10: ...ime 11 Copying 6 Phase 2 Heat READ ONLY CALCULATED INTERNALLY BY ADDING PHASE HOLD TIMES 3 Enter and Exit Edit Mode ToentereditmodepressandholdtheDOWNarrow key for 3 seconds the solid RED LED will bli...

Страница 11: ...ge the setting number Press the arrow keys on the left display View the values on the right display Press both keys Settings Setting 99 Duty Cycle Length Do Not Change Factory set at 06 03 30 seconds...

Страница 12: ...g towels may harm the unit 1 Turn unit off and allow cooling for 10 minutes 2 Removeallholdingpansandwash rinseandsanitize at the 3 compartment sink Allow to air dry 3 Spray a sanitizer soaked towel w...

Страница 13: ...depending on the programmed hold times Troubleshooting Check that the Warmer control powers up and the Warmer heats up If not call Duke Mfg for Warmer service at 314 231 1130 or 800 735 3853 Service...

Страница 14: ...6 12 12 12 18 18 18 8 159149 Block Terminal 2 Bar 8 Tab with fuse holder 1 1 1 9 159077 Relay Mini FS24D20 06 2 4 6 10 600143 600145 Kit IRHU Control Ver 13 Kit IRHU Control Ver 16 1 1 1 1 1 1 11 159...

Страница 15: ...15 Installation and Operation of IRHU 11 2 3 4 16 25 15 20 21 10 7 5 1 18 12 14 17 23 22 9 8 13 IHRU 22 Exploded View...

Страница 16: ...12 12 8 159149 Block Terminal 2 Bar 8 Tab with fuse holder 1 9 159077 Relay Mini FS24D20 06 4 10 600143 600145 Kit IRHU Control Ver 13 Kit IRHU Control Ver 16 1 1 11 159080 Current Sensor with Connec...

Страница 17: ...17 Installation and Operation of IRHU IHRU 41 Exploded View 13 12 18 16 15 7 3 4 24 17 23 2 14 8 9 22 20 21 10 1 5...

Страница 18: ...Installation and Operation of IRHU 18 WIRING DIAGRAMS DUKE INFRARED HOLDING UNIT MODEL IRHU 12 208 240 VAC 50 60 HZ 1 PH...

Страница 19: ...19 Installation and Operation of IRHU DUKE INFRARED HOLDING UNIT MODEL IRHU 22 208 230 240 VAC 50 60 HZ 1 PH...

Страница 20: ...Installation and Operation of IRHU 20 DUKE INFRARED HOLDING UNIT MODEL IRHU 23 208 230 240 VAC 50 60 HZ 1 PH...

Страница 21: ...21 Installation and Operation of IRHU DUKE INFRARED HOLDING UNIT MODEL IRHU 41 208 230 240 VAC 50 60 HZ 1 PH...

Страница 22: ...SERVICE DUKE EMEA UK IRELAND NORDIC COUNTRIES Duke Manufacturing UK Ltd Unit 10 Greendale Business Park Woodbury Salterton Exeter EX5 1EW Phone 44 0 1395 234140 Fax 44 0 1395 234154 service exeter duk...

Страница 23: ...23 Installation and Operation of IRHU NOTES...

Страница 24: ...2 Jazlovice Ricany Building number DC 4 on the ProLogis Park Prague D1 West Prague 251 01 Czech Republic Phone 420 257 741 033 Fax 420 257 741 039 Duke EMEA UK Ireland Nordic Countries Duke Manufactur...

Отзывы: