Installation and Operation of IRHU

 

Any YELLOW light may be pressed again to 

unmark that pan. 

 

Exit edit mode to complete the copy.

7.  Select Another Pan.

 

To  select  the  top  pan  or  bottom  pan 

p r e s s   b o t h   a r r o w   k e y s   t o g e t h e r. 

The solid RED light will switch to the other pan. 

To select another pair of pans press both arrow keys 

by that pair. The numbers will light and the solid 

red light will move to the bottom of that pair.

Press both keys

8.  Exit Programming Mode
 

Review  all  settings  as  in  step  2.  Turn  off 

the  power  to  the  unit  and  then  back  on  – 

the unit will be in the normal operation mode.

SETUP MODE

1.  Enter Setup Mode

 

Turn the power off. 

 

Then while powering on press and hold the 2 keys 

closest to the ON/OFF switch.

 

1 solid RED light will turn on.

 

The 2 displays will show numbers.

 

All other displays will go out.

Press both keys

2.  Select and View Settings

 

The left display shows the setting number

 

The right display shows the value

 

To change the setting number:

 

Press the arrow keys on the left display.

 

View the values on the right display.

Press both keys

Settings:

Setting # 99 – 

Duty Cycle Length

•  Do Not Change. Factory set at 06

•  03 = 30 seconds

•  06 = 60 seconds

•  12 = 120 seconds.

Setting # 98

 – Phase 4 On - % Heat

•  Do Not Change. Factory set at 30

•  0 to 99, and FF = 100%

Setting # 97

 – Active Keyboards

•  01 -  Back Only, 02 – Front Only  (1X2 & 1X3)

•  01 - Front Only, 02 – Back Only  (2x2)

•  03 - Both Front and Back Active

Setting # 96

 – Firmware Revision

•  Displays firmware version

Setting # 95

 – Max Temperature

•  Displays  the  max  electrical  compartment 

temperature in °C (00 Resets to 0°C)

Setting # 94

 – Actual Temperature

•  Displays  the  actual  electrical  compartment 

temperature in °C.

Setting # 93

 – IR unit holding type

•  Change in edit mode to override until the next 

power up.

Setting # 92

 – Current Monitor

•  Do Not Change. Factory Set at 01.

•  01 – Current monitoring

•  00 – No current monitoring (until power off)

Setting # 91

 – Reset to factory default

•  01 – Reset

Setting # 90

 – Jumper Installed

•  Change in edit mode to override until the next 

power up.

Setting # 89

 – Factory Setting

•  Do Not Change.

Setting # 88

 – Factory Setting

•  Do Not Change.  (This setting does not exist 

in some programming.)

Содержание IRHU Series

Страница 1: ...production without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 8...

Страница 2: ...OTENTIAL EARTHING TERMINAL EXPORT ONLY 9 DIGITAL TIMERS 9 DIGITAL TIMER DISPLAYS 9 OPERATING INSTRUCTIONS 10 PROGRAMMING MODE 10 Settings 10 SETUP MODE 11 Settings 11 CARE AND CLEANING 12 CLEANING GUI...

Страница 3: ...tastetransfer Becausethecompartments aresealed nodisassemblyisrequiredforcleaningand product changes The unique design of the Duke IR Holding Unit allows theIRenergytobeprogrammedforeachcompartment Th...

Страница 4: ...gs and cautions appear throughout this manual and should be carefully observed Turn the unit off disconnect the power source and allow unit to cool down before performing any service or maintenance on...

Страница 5: ...0 230 11 7 IRHU 22XXXX 240 240 11 3 IRHU 23XXXX 208 245lbs 111 Kg 208 19 5 4050 IRHU 23XXXX 230 230 17 6 IRHU 23XXXX 240 240 16 9 IRHU 41XXXX 208 175lbs 80 Kg 208 13 2700 IRHU 41XXXX 230 230 11 7 IRHU...

Страница 6: ...7 8 835 03 mm 23 3 4 603 25 mm 15 380 31 mm 509L COOKING APPLIANCE DE CUISINE UNDERWRITERS LABORATORIES INC IN ACCORDANCE WITH NSF NO 4 1999 IHRU 23 Twist Lock Plug Schuko Plug 603 25 mm 1214 81 mm 12...

Страница 7: ...U 41 Twist Lock Plug Schuko Plug 2 1 8 53 98 mm 2 1 2 63 89 mm 29 7 8 759 mm 17 7 8 454 96 mm 1 1 8 29 91 mm 23 5 8 601 40 mm 509L LISTED APPLIANCE DE CUISINE ALSO CLASSIFIED BY UNDERWRITERS LABORATOR...

Страница 8: ...Stop Note the style of pan stop varies by model 5 4 IRHU 12 IRHU 22 IRHU 23 Rear View 4 Programming Connection Port 5 Power Cord with Strain Relief IRHU 41 FEATURES 1 2 3 IRHU 41 Front View 1 Power O...

Страница 9: ...To avoid risk of electrical shock or death this unit must be grounded and plug must not be altered EARTHING INSTRUCTIONS Grounding reduces risk of electric shock by providing an escape wire for the el...

Страница 10: ...ime 11 Copying 6 Phase 2 Heat READ ONLY CALCULATED INTERNALLY BY ADDING PHASE HOLD TIMES 3 Enter and Exit Edit Mode ToentereditmodepressandholdtheDOWNarrow key for 3 seconds the solid RED LED will bli...

Страница 11: ...ge the setting number Press the arrow keys on the left display View the values on the right display Press both keys Settings Setting 99 Duty Cycle Length Do Not Change Factory set at 06 03 30 seconds...

Страница 12: ...g towels may harm the unit 1 Turn unit off and allow cooling for 10 minutes 2 Removeallholdingpansandwash rinseandsanitize at the 3 compartment sink Allow to air dry 3 Spray a sanitizer soaked towel w...

Страница 13: ...depending on the programmed hold times Troubleshooting Check that the Warmer control powers up and the Warmer heats up If not call Duke Mfg for Warmer service at 314 231 1130 or 800 735 3853 Service...

Страница 14: ...6 12 12 12 18 18 18 8 159149 Block Terminal 2 Bar 8 Tab with fuse holder 1 1 1 9 159077 Relay Mini FS24D20 06 2 4 6 10 600143 600145 Kit IRHU Control Ver 13 Kit IRHU Control Ver 16 1 1 1 1 1 1 11 159...

Страница 15: ...15 Installation and Operation of IRHU 11 2 3 4 16 25 15 20 21 10 7 5 1 18 12 14 17 23 22 9 8 13 IHRU 22 Exploded View...

Страница 16: ...12 12 8 159149 Block Terminal 2 Bar 8 Tab with fuse holder 1 9 159077 Relay Mini FS24D20 06 4 10 600143 600145 Kit IRHU Control Ver 13 Kit IRHU Control Ver 16 1 1 11 159080 Current Sensor with Connec...

Страница 17: ...17 Installation and Operation of IRHU IHRU 41 Exploded View 13 12 18 16 15 7 3 4 24 17 23 2 14 8 9 22 20 21 10 1 5...

Страница 18: ...Installation and Operation of IRHU 18 WIRING DIAGRAMS DUKE INFRARED HOLDING UNIT MODEL IRHU 12 208 240 VAC 50 60 HZ 1 PH...

Страница 19: ...19 Installation and Operation of IRHU DUKE INFRARED HOLDING UNIT MODEL IRHU 22 208 230 240 VAC 50 60 HZ 1 PH...

Страница 20: ...Installation and Operation of IRHU 20 DUKE INFRARED HOLDING UNIT MODEL IRHU 23 208 230 240 VAC 50 60 HZ 1 PH...

Страница 21: ...21 Installation and Operation of IRHU DUKE INFRARED HOLDING UNIT MODEL IRHU 41 208 230 240 VAC 50 60 HZ 1 PH...

Страница 22: ...SERVICE DUKE EMEA UK IRELAND NORDIC COUNTRIES Duke Manufacturing UK Ltd Unit 10 Greendale Business Park Woodbury Salterton Exeter EX5 1EW Phone 44 0 1395 234140 Fax 44 0 1395 234154 service exeter duk...

Страница 23: ...23 Installation and Operation of IRHU NOTES...

Страница 24: ...2 Jazlovice Ricany Building number DC 4 on the ProLogis Park Prague D1 West Prague 251 01 Czech Republic Phone 420 257 741 033 Fax 420 257 741 039 Duke EMEA UK Ireland Nordic Countries Duke Manufactur...

Отзывы: