STEP 13 -
Specify Process Limits Behavior
For each limit that is important to your application, use the drop down menu, and select Display. See Figure 3-14.
These parameters will be displayed on the Cycle Data screen, and may be important for subsequent analysis of the weld
process.
Once the process settings are fully developed for the application, the Process Limits can be set to Suspect and/or Bad to
identify part assemblies of inferior weld quality.
Static Hold Method
After the completion of dynamic hold, if enabled, the press motion stops for a specified amount of time to allow for molten
plastic to solidify. This phase is called static hold.
To program static hold, set the Static Hold Method to Time, and enter the desired Hold Time. Once the static hold phase is
complete, the press retracts back to the Top-of-Stroke position.
This unique feature allows for superior consistency on overall part height. This is unlike a pneumatic press that continues to
compress the part during the hold phase. In addition, Static Hold can contribute to stronger weld bonds. See Figure 3-13
below.
Figure 3-13
Static Hold Method
Figure 3-14
Process Limits Tab
Process Limits Tab
Содержание IQ Explorer 3
Страница 1: ...IQ Explorer 3 Globe Americas www dukane com ENVELOPE ussales dukane com QUICK START GUIDE ...
Страница 4: ...S ECTI ON 1 I NTROD UCTI ON IQ Explorer 3 QUICK START GUIDE 1 SECTION 1 Introduction ...
Страница 7: ...IQ Explorer 3 QUICK START GUIDE 4 SECTION 2 Cable Connections ...
Страница 11: ...IQ Explorer 3 QUICK START GUIDE 8 SECTION 3 Operation ...
Страница 23: ...Please refer to our website at www dukane com contact us to locate your local representative ...