ON LINE
-
After AC power has been activated and the
press is operating normally, ON LINE is the normal op-
erating mode. The press can produce ultrasound signals
in this mode.
The word, Online appears in a white outlined box in the
upper right of the display.
TEST
-
After AC power has been activated and the press
is operating normally, in the ON LINE mode, the TEST
key can be pushed.
This activates a momentary ultrasound pulse allowing the
operator to test system function. The display will show the
real time settings for
Amplitude
,
Power
,
Operating Fre-
quency
, and
Distance
(does not appear if distance is not
supported). This information is useful in troubleshooting.
While pushing the
TEST
key, look at the System Power
Output Level bar graph (See Figure 4-3.) There should be
at least one segment lit.
IMPORTANT
- If more than three segments are lit, with
no load applied to the ultrasonic stack, make sure the stack
is properly assembled and not damaged. During normal
operation, the peak level LED segment remains lit (ap-
proximately 1 second) until the next cycle begins.
OFFLINE
-
After AC power has been activated and the
press is operating normally, the
OFFLINE
key may be
pressed to put the press into the offline mode. In this mode
the press can not generate an ultrasound signal.
However the press can still run a cycle while OFFLINE.
This can be useful to check the rest of the mechanical
weld setup including the speed, air pressure and trigger
point settings.
The word,
Offline
appears in a white outlined box in the
display's upper right corner.
If a transducer is not connected
to the ultrasound output con-
nector, the system should be
set to the OFFLINE mode. Do not ac-
tivate the ultrasound output without a
transducer connected. Make sure that
the stack is properly assembled before
it is connected to the system. The horn
should never come in direct contact with
a metal fixture or anvil with ultrasound
activated.
CAUTION
System Operating Mode Keys
Figure 4-2
Display Detail, Operating Mode Indicator
Operating Mode Indicator
Online condition shown
System Power Output Level
Bar Graph
PART COUNT: 0
WELD TIME : 0.000s
SETUP #01
STATISTICS
PROCESS
PEAK POWER : 0 W
ENERGY: 0J
ONLINE
AUTO 01
DISTANCE 0in
Figure 4-3
Display Detail, Power Output Level
PART COUNT: 0
WELD TIME : 0.000s
SETUP #01
STATISTICS
PROCESS
PEAK POWER : 0 W
ENERGY: 0J
ONLINE
AUTO 01
DISTANCE 0in
Page 36
iQ Series
Ultrasonic Integrated Press System i 220 User’s Manual
Dukane Manual Part No. 403-594-02
Содержание i220
Страница 7: ...This page intentionally left blank Page vii Dukane Manual Part No 403 594 02 ...
Страница 107: ...SECTION 10 Contacting Dukane Page 99 Dukane Manual Part No 403 594 02 Section 10 Contact Dukane ...
Страница 127: ...SECTION 13 Index Page 119 Dukane Manual Part No 403 594 02 Section 13 Index ...