Automation System
User-supplied automation equipment connects to the press
System I/O Panel through:
•
•
J1
- User-supplied external controls provide the press with
input/output signals that direct operation of the press.
Table 3-I - System Input/Output Connector Signals
-
shows
the 25-pin connector's input and output signal names.
See Pages 21-23 for signal descriptions.
J6
- Attach the finished end (9-pin female connector) of
Dukane cable Part Number 200-1546-xxM
**
to J6 on the
Press System I/O Panel. With the open end of the cable the
user can make connections from user-supplied equipment
to provide for the functions the Dukane cable typically has.
See the table below.
Pin No.
Type
Function
Signal Description
1
Input
Activation Switch 1 N.O.
Normally Open (N.O.) dry contact closure to Pin 7
2
Input
Activation Switch 2 N.O.
Normally Open (N.O.) dry contact closure to Pin 7
3
Input
Hardware Abort Power In
Normally Closed (N.C.) emergency switch contact
4
Input
Software Abort
Normally Open (N.O.) dry contact closure to ground
5
Ground
Internal Ground
Internal Ground (Gnd)
6
Input
Activation Switch 1 N.C.
Normally Closed (N.C.) dry contact closure to Pin 7
7
+22VDC
Switch Power Out
Power for switches when abort inactive.
8
Input
Activation Switch 2 N.C.
Normally Closed (N.C.) dry contact closure to Pin 7
9
+22VDC
Hardware Abort Power Out
Normally Closed (N.C.) emergency switch contact
Table 3-III
Dukane Cable 200-1546-00 Signals
xxM = A value representing cable length in Meters.
This number is typically determined when ordering the equipment.
**
J1, a 25-pin connector, and
J6, a 9-pin connector.
Page 31
Dukane Manual Part No. 403-594-02
Section 3 - Installation
Содержание i220
Страница 7: ...This page intentionally left blank Page vii Dukane Manual Part No 403 594 02 ...
Страница 107: ...SECTION 10 Contacting Dukane Page 99 Dukane Manual Part No 403 594 02 Section 10 Contact Dukane ...
Страница 127: ...SECTION 13 Index Page 119 Dukane Manual Part No 403 594 02 Section 13 Index ...