background image

3

Section I 

General Information

1-1. General

This manual contains maintenance instructions for Duff 
Norton translating machine screw actuators of two ton 
to 75 ton capacity. It describes and details procedures 
for installation, disassembly, cleaning, inspection, and 
assembly of these actuators.

1-2. Applications

Industrial Use Only

  The actuators described and 

illustrated in this manual are intended for industrial use 
only and should not be used to lift, support or otherwise 
transport people unless you have a written statement 
from Duff-Norton which authorizes the specific actuator 
unit, as used in your application, as suitable for moving 
people. 

These actuators are intended for a clean, non-corrosive 
environment with ambient temperatures ranging from -20 
to 200 ° F. If your environment is dirty and/or contains 
abrasive particles it is important to protect the screw with 
a boot. If your atmosphere is corrosive it is important to 
specify a non-corrosive material or finish. Duff-Norton 
can provide stainless steel, nickel plated or epoxy coated 
actuators. If your duty is high or your use severe, more 
frequent lubrication should be employed. Duff-Norton 
publishes a Mechanical Actuator Design Guide, Catalog 
No. 2003, which you may find helpful in the selection 
and application of mechanical actuators. If you need 
additional help, please contact Duff-Norton at (800) 477-
5002.

1-3. Specifications

Table 1-1. 1800 (2000) and 9000 (10000) Series

Standard Actuator 
Model No. 

Upright

1802
9002

9005

9010

9015

9020

9025

9035

1850
9050

9075

Inverted

1801
9001

9004

9009

9019

9019

9024

9034

1849
9049

9074

Special Actuator 
Model No. 

Upright

2002

10002

10005

10010

10015

10020

10025

10035

2050

10050

10075

Inverted

2001

10001

10004

10009

10014

10019

10024

10034

2049

10049

10074

Rated Load (tons)

2

5

10

15

20

25

35

50

75

Diameter of Lifting Screw (Inches)

1

.250 Pitch

Acme

1-1/2

.375 Pitch

Acme

2

.500 Pitch

Acme

2-1/4

.500 Pitch

Acme

2-1/2

.500 Pitch

Acme

3

.666 Pitch

Acme

3-3/4

.666 Pitch

Acme

4-1/2

.666 Pitch

Square

5

.666 Pitch

Square

Closed Height** (Inches)

5-1/4

7

7-1/4

8

9-1/4

11

12

13

16-1/2

Base Size (Inches)

3-1/2 x 7

4-1/8 x 

6-1/4

6 x 8

7-1/2 x 

8-3/4

7-3/4 x 

9-1/4

8-1/4 x 11

10-1/4 x 

13-3/4

10-1/4 x 

15-1/2

9-3/4 x 19-3/4

10-1/2 x 

21-3/4

14 x 23

Worm Gear Ratios

Std Ratio

6:1

6:1

8:1

8:1

8:1

10-2/3:1

10-2/3:1

10-2/3:1

10-2/3:1

Optional

24:1

24:1

24:1

24:1

24:1

32:1

32:1

32:1

32:1

Turns of Worm For 
1-inch Raise

Std Ratio

24

16

16

16

16

16

16

16

16

Optional

96

64

48

48

48

48

48

48

48

Maximum H.P. Per 
Actuator

Std Ratio

2

4

5

5

5

8

8

15

15

Optional

1/2

3/4

1-1/2

1-1/2

1-1/2

2-1/2

2-1/2

6

6

Torque at Full Load* 
(in-lbs)

Std Ratio

120

450

750

1430

2050

2700

4000

7500

12000

Optional

50

185

400

820

1170

1200

2400

4200

6600

Actuator Efficiency 
Rating (%)

Std Ratio

23.2

22.1

23.7

20.2

18.8

18.7

15.8

13.8

12.4

Optional

13.3

12.1

15.1

12.9

12.0

10.5

8.9

8.3

7.5

Weight with Base Raise of 6 inch 
(lbs)

17

35

52

66

93

160

240

410

650

Weight for Each Additional 1 inch of 
Raise (lbs)

.33

.85

1.4

1.5

2.6

2.5

3.7

5.5

6.5

*  For loads from 25% to 100% of actuator load rating. Torque requirements are approximately proportional to the load. 
**  Closed heights are for standard upright top plate models and may vary with different screw end, inverted models, or when bellows boot is used. 

Содержание SK-2389-T

Страница 1: ...Publication Part No SK 2389 T...

Страница 2: ...anty Repair 5 Section II Maintenance 2 1 Lubrication 6 2 2 Rebuild Procedure 6 2 3 Required Tools 6 2 4 Disassembly 6 2 5 Cleaning 6 2 6 Inspection 7 2 7 Assembly 7 2 8 Anti Backlash Nut Function 7 Fi...

Страница 3: ...Inverted 1801 9001 9004 9009 9019 9019 9024 9034 1849 9049 9074 Special Actuator Model No Upright 2002 10002 10005 10010 10015 10020 10025 10035 2050 10050 10075 Inverted 2001 10001 10004 10009 10014...

Страница 4: ...ame as for Series 1800 and 9000 See Table 1 For loads from 25 to 100 of actuator load rating Torque requirements are approximately proportional to the load Closed heights are for standard upright top...

Страница 5: ...ting screw thread is recommended to check wear of the worm gear internal threads The normal backlash on a new unit of this type is approximately 010 inch Backlash of 50 or more of the thread thickness...

Страница 6: ...way 6 Replace damaged or frozen lubrication fittings with new ones 2 3 Required Tools A bearing puller or press and common hand tools are necessary for proper assembly and disassembly 2 4 Disassembly...

Страница 7: ...5a On 5 ton 35 ton and 75 ton models press load bearing cones onto worm gear 6A or worm gear and nut assembly 6B 6 Install worm gear 6A or worm gear and nut assembly 6B in shell 3 NOTE Strike each en...

Страница 8: ...an exploded illustration of the 1800 9000 4800 and 9400 Series translating machine screw actuators The number adjacent to each part on the illustration is the index number Keyed to this index number...

Страница 9: ...9 A B Figure 3 2 Exploded Illustration 1800 2000 9000 10000 4800 5800 and 9400 10400 Series Translating Machine Screw Actuators...

Страница 10: ...10 Notes...

Страница 11: ...11...

Страница 12: ...strial Products Inc Duff Norton Division May not be copied in whole or in part Printed in the USA P O Box 7010 Charlotte NC 28241 7010 Phone 800 477 5002 704 588 4610 Fax 704 588 1994 Email duffnorton...

Отзывы: