background image

SISTEMA PHOTON - manuale d'installazione - pag.12

 

 

 

 

Fig 25 

 

 

Fig 26 

WARNING: DO NOT LOOSEN SCREWS (1-8) 

INSIDE THE CAPS 

THEIR TAMPERING WILL CAUSE LOSS OF WARRANTY RIGHTS, AS WELL AS LOSS 

OF THE DECLARED IP LEVEL 

CABLE GLAND MOUNTING 

MANDATORY

 

THE SUPPLIED CABLE GLANDS ENSURE 
THE IP65 GRADE. 
IT’S MANDATORY FOR THE INSTALLER 
TO MOUNT THEM PROPERLY. 
THE NON-COMPLIANCE TO THIS 
RECOMMENDATION HEAVILY AFFECTS 
THE OPERATION AND WILL CAUSE LOSS 
OF WARRANTY RIGHTS. 

Содержание Photon System

Страница 1: ...configuration of the system and concentrate the connexion with the control panel The hub will manage up to a maximum of four couples that can be installed even in the same area and the beams will not...

Страница 2: ...om the hub a standard 4 wire cable two for power supply 0 75 mm2 2 for the serial communication 0 22 mm2 and shield The number of possible connection typologies is quite wide and for each one of that...

Страница 3: ...n Cable connection inside the bars The cable connection is made in the following steps 1 Prepare the cable Fig 8 A B 2 Insert the cable in the cable gland Fig 9 3 Fold the cable shield backwards and l...

Страница 4: ...w of contacts on which a jumper is inserted in the position corresponding to the address to assign to the bar Fig 11 Fig 11 Addressing of the NOT HEATED version HEATED version due to the presence of t...

Страница 5: ...intend to manage the stand by separately They can also be connected all together in order to have not separate stand by for the different couples When the barriers are in stand by the beams are not a...

Страница 6: ...nected bars are detected by the software 1 2 3 4 5 6 7 8 If some bar is not detected check that the addresses on the bars and the connections are correct then make again the test Do not go to the next...

Страница 7: ...ssion is in the direction on the red sign on the ROTAX Fig 17 5 Do the same operation on the other bar of the couple 6 Connect the TBS tester to dedicated plug inside the ROTAX cap Fig 16 7 Turn on th...

Страница 8: ...nnected to the dedicated plug inside the ROTAX cap of the bars Fig 26 It is sufficient to connect to any of the bars or to the HUB to check the whole system Though a selector you can select the couple...

Страница 9: ...and archive everything happens in the system The software allows you to store all system events with the time in which they occurred This allows you to keep track of them for many months Through a que...

Страница 10: ...PHOTON SYSTEM Installation Guide v8 0 pag 10 SUMMARY TABLES Fig 23...

Страница 11: ...SISTEMA PHOTON manuale d installazione pag 11 Fig 24...

Страница 12: ...G WILL CAUSE LOSS OF WARRANTY RIGHTS AS WELL AS LOSS OF THE DECLARED IP LEVEL CABLE GLAND MOUNTING MANDATORY THE SUPPLIED CABLE GLANDS ENSURE THE IP65 GRADE IT S MANDATORY FOR THE INSTALLER TO MOUNT T...

Страница 13: ...SISTEMA PHOTON manuale d installazione pag 13...

Страница 14: ...SISTEMA PHOTON manuale d installazione pag 14 HUB TC...

Страница 15: ...the wire to be used for a connection to a maximum distance of 50 mts from the power supply In any case the external diameter of the connection cable must not be more than 6 8mm MODEL VOLTAGE COURRENT...

Страница 16: ...SISTEMA PHOTON manuale d installazione pag 16...

Страница 17: ...SISTEMA PHOTON manuale d installazione pag 17...

Страница 18: ...ighten only one of two fixing screws a and leave moving possibility to the second screw to ensure the profile of barrier free to expand contract for thermal expansion The bar must not bend under any c...

Страница 19: ...SISTEMA PHOTON manuale d installazione pag 19...

Страница 20: ...SISTEMA PHOTON manuale d installazione pag 20 MANUALS AND SOFTWARES AVAILABLE ON WEBSITE www duevi eu INSTALLER SUPPORT support duevi eu...

Отзывы: